Release Notes
System Release 13.4
pmp-0979 - July 2015
Page
27 of
50
Table 20
Spectrum Analyzer Options configuration
Attribute
Meaning
SM/BHS Scanning
Bandwidth
Selecting channel bandwidth for scanning. It is only
applicable for SM or BHS to scan spectrum for selected
channel bandwidth, whereas BHM will scan for currently
configured bandwidth.
2)
Go to
Tools > Spectrum Analyzer > Min and Max Frequencies
tab.
Table 21
Spectrum Analyzer – Min and Max Frequencies configuration
Attribute
Meaning
Min and Max
Frequencies in KHz
Enter minimum and maximum range of frequencies for
Spectrum analysis in KHz
Set Min And Max To Full
Scan
On button click, full support range of radio populated as
minimum and maximum frequencies
Set Min And Max To
Center Scan +/- 40 MHz
On button click, minimum and maximum frequencies are
populated from center fre/- 40 MHz
3)
Go to
Tools > Spectrum Analyzer > Timed Spectrum Analyzer
tab.
Table 22
Spectrum Analyzer – Timed Spectrum Analyzer configuration
Attribute
Meaning
Duration
Enter scanning duration in second (10 to 1000) to
perform spectrum analysis.