Chapter 3: System planning
183
Figure 69 :
Remote AP wired to SM that serves as a relay
Passing Sync sig nal
Passing Sync in a Single Hop
Network sync can be passed in a single hop in the following network designs:
l
Design 1
o
A CMM provides sync to a co-located AP.
o
This AP sends the sync over the air to SMs.
l
Design 2
o
A CMM provides sync to a co-located BH timing master.
o
This BH timing master sends the sync over the air to a BH timing slave.
Passing Sync in an Addit ional Hop
Network sync can be extended by one additional link in any of the following network designs:
Note
In each of these following designs, Link 2 is not on the same frequency band as
Link 4. (For example, Link 2 may be a 5.2 GHz link while Link 4 is a 5.7 or 2.4 GHz
link.)
l
Design 3
o
A CMM provides sync to a co-located AP.
o
This AP sends the sync over the air to an SM.
o
This SM delivers the sync to a co-located AP.
o
This AP passes the sync in the additional link over the air to SMs.