PMP 450 Planning Guide
Calculation of lateral force (US)
The magnitude of the lateral force can be estimated from:
Force (in pounds) = 0.0042Av
2
Where:
Is:
A
surface area in square feet
v
wind speed in miles per hour
The lateral force produced by a single PMP 450 unit at different wind speeds is shown in
Table 28 Lateral force - US
Largest surface area (square
feet)
Lateral force (lb) at wind speed
(miles per hour)
80
100
120
140
150
0.71 (AP – 5 GHz, 60 Degree Sector)
19
30
43
58
67
0.89 (AP – 5 GHz, 90 Degree Sector)
24
37
54
73
84
2.9 (AP – 2.4 GHz, 60 Degree Sector)
78
122
175
239
274
0.94 (AP – 3.5 GHz, 90 Degree Sector)
25
40
57
77
89
0.94 (AP – 3.6 GHz, 90 Degree Sector)
25
40
57
77
89
0.29 (SM)
7.8
12
18
23
27
Capabilities of the PMP 450 Series
The structure and mounting brackets of the AP are capable of withstanding wind speeds up to:
•
190 kph (118 mph) – 5 GHz Sector Antennas
•
216 kph (135 mph) – 2.4 GHz, 3.5 GHz, 3.6 GHz Sector Antennas
Ensure that the structure to which the AP is fixed to is also capable of withstanding the prevalent wind speeds and
loads.
The structure and mounting brackets of the SM are capable of withstanding wind speeds up to 190 kph (118 mph).
Ensure that the structure to which the SM is fixed to is also capable of withstanding the prevalent wind speeds and
loads.
pmp-0047 (March 2014)
1-67
Summary of Contents for PMP 450
Page 1: ...Cambium PMP 450 Planning Guide System Release 13 1 ...
Page 13: ...PMP 450 Planning Guide pmp 0047 March 2014 1 3 ...
Page 42: ...PMP 450 Planning Guide Figure 14 Custom Frequency tab of the SM 1 32 pmp 0047 March 2014 ...
Page 58: ...PMP 450 Planning Guide Figure 16 AP web based management screenshot 1 48 pmp 0047 March 2014 ...
Page 82: ...PMP 450 Planning Guide 1 72 pmp 0047 March 2014 ...
Page 155: ...PMP 450 Planning Guide pmp 0047 March 2014 1 145 ...