Chapter 5: Installation
Installing the ODU and top LPU
Connectorized ODU
1 (a) Line up the bolt heads with receptacles in the ODU. (b) Fix the mounting plate and bracket
bolts to the back of the ODU using the bolts and washers. Tighten to a torque setting of 5 Nm (4
lb ft).
(a) Receptacles for bracket bolts:
(b) Mounting plate fixed:
2 Hoist the ODU up to its position on the mounting pole.
3 (a) For back-to-back LPU mounting, fix the ODU to the pole using the LPU.
(b) For separate LPU mounting, fix the ODU to the pole using the bracket strap.
(c) Back-to-back LPU:
(d) Separate LPU:
4 Tighten the mounting bolts to a torque setting of 7 Nm (5.5 lb ft). Do not over-tighten the bolts,
as this may lead to failure of the assembly.
Page
5-9