PTP 800 Series User Guide
I nst alling t he I F and ground cables
phn- 2513_004v000 ( Oct 2012)
5- 49
Hoisting the main IF cable
Use hoisting grips to hoist the main IF cable safely up a tower or building and provide
permanent support so that mechanical connection to an antenna can be made. The correct
hoisting grip for CNT-400 IF cable is Cambium part number 07009304001, used with the
correct crimp tool SG-IT (Andrew part number 243333).
Failure to obey the following precautions may result in injury or death.
Observe the following precautions:
•
Use the hoisting grip to hoist one cable only. Attempting to hoist more than one cable
may cause the hoisting grip to break or the cables to fall.
•
Do not use the hoisting grip for lowering cable unless the clamp is securely in place.
•
Do not reuse hoisting grips. Used grips may have lost elasticity, stretched, or become
weakened. Reusing a grip can cause the cable to slip, break, or fall.
•
Use hoisting grips at intervals of no more than 60 m (200 ft).
•
Use the proper hoisting grip for the cable being installed. If the wrong hoisting grip is
used, slippage or insufficient gripping strength will result.
Attaching the hoisting grip
Attach one or more hoisting grips to the main IF cable before fitting the N type connector
to the top end (as described in
). Attach one additional
hoisting grip for each 60 m (200 ft) of cable.
Summary of Contents for PTP 800 Series
Page 1: ...Cambium PTP 800 Series User Guide System Release 800 05 02 ...
Page 40: ...Licensing requirements About This User Guide 10 phn 2513_004v000 Oct 2012 ...
Page 232: ...Limit of liability Chapter 3 Legal information 3 22 phn 2513_004v000 Oct 2012 ...
Page 322: ...Radiation hazard assessm ent Chapter 4 Reference information 4 90 phn 2513_004v000 Oct 2012 ...
Page 428: ...Replacing IRFU components Chapter 5 Installation 5 106 phn 2513_004v000 Oct 2012 ...
Page 630: ...Using recovery mode Chapter 7 Operation 7 78 phn 2513_004v000 Oct 2012 ...