I nst alling t he I F and ground cables
phn- 2513_004v000 ( Oct 2012)
5- 53
To install and ground the main IF cable, proceed as follows:
1
Attach the N type connector at the top end of the main IF cable to the SURGE
port of the top LPU.
2
Protect the N type connectors on the LPU from the weather by applying self-
amalgamating and PVC tape, as described in
3
Lay the main IF cable as far as the building entry point, ensuring there is enough
length to extend through the wall of the building to the bottom LPU.
4
Attach the main IF cable to the supporting structure using the cable ties
provided.
5
Ground the IF cable at the points specified in
Protection requirements for a mast
Making an IF cable ground point