I nst alling t he CMU
Chapt er 5: I nst allat ion
5- 80
phn- 2513_004v000 ( Oct 2012)
Figu r e 9 7
CMU wit h rack m ount ing kit and blanking plat e
Figu r e 9 8
CMU m ount ed in rack
To avoid damaging the RF cable, route it in such a way that the minimum bend radius for
the selected cable is always exceeded.
If cables are laid in an air-handling cavity, they must be Plenum rated.
Grounding the CMU
Ground the CMU to a rack ground bar, master ground bar or other suitable ground using a
minimum cable cross section of 10 mm
2
(6AWG) (
). It is a condition of the safety
approval that the unit is grounded.
For a 1+1 Hot Standby link, ground both CMUs to the same grounding point (
).
Attach the ground cable to the CMU ground connector (