PTP 800 Series User Guide
I nst alling t he CMU
phn- 2513_004v000 ( Oct 2012)
5- 83
Figu r e 1 0 1
Cam bium AC t o DC conv ert er
For details of alternative power supply arrangements, refer to
. If an alternative power supply is to be installed, ensure that it meets the
following safeguards:
•
The DC supply has over current protection that does not exceed 3 amps
•
There is a way to isolate the CMU from the DC supply.
If a DC connector has to be attached to the DC output cable, use the following pin
connections:
•
Pin 1:
−
48 Volts
•
Pin 2: 0 Volts
•
Pin 3: Not Connected
•
Pin 4: Chassis ground
Pin 1 is the left most pin on the CMU power connector when looking at the front panel.