Task 2: Configuring I P and Et hernet int erfaces
Chapt er 6: Configurat ion and alignm ent
6- 14
phn- 2513_004v000 ( Oct 2012)
Ta ble 2 2 2
Managem ent port at t ribut es
At t r ibu t e
M e a n in g
Management Port
Wireless Down Alert
Only displayed when the Management Mode attribute is set to
‘Out-of-Band Local’.
If a condition is detected where the link can no longer forward
management traffic in one or both directions, for example, a
wireless fade or equipment failure, then if this attribute is
enabled the management port will be briefly disconnected
from the network. This signals to the connected network
equipment that this link is no longer available for
management traffic. Enabling this feature can be beneficial in
complex networks where alternative routes provide continued
service in the event of link failure (see
Management Port Auto
Negotiation
‘Enabled’ means that configuration of the out-of-band
management Ethernet interface is automatically negotiated.
This is the default setting.
‘Disabled’ means that configuration is forced.
Use the same setting for both ends of the link.
Ensure that this attribute has the same setting in the CMU
and in connected network equipment. If they are not
consistent, then a duplex mismatch will occur, resulting in
greatly reduced data capacity.
Summary of Contents for PTP 800 Series
Page 1: ...Cambium PTP 800 Series User Guide System Release 800 05 02 ...
Page 40: ...Licensing requirements About This User Guide 10 phn 2513_004v000 Oct 2012 ...
Page 232: ...Limit of liability Chapter 3 Legal information 3 22 phn 2513_004v000 Oct 2012 ...
Page 322: ...Radiation hazard assessm ent Chapter 4 Reference information 4 90 phn 2513_004v000 Oct 2012 ...
Page 428: ...Replacing IRFU components Chapter 5 Installation 5 106 phn 2513_004v000 Oct 2012 ...
Page 630: ...Using recovery mode Chapter 7 Operation 7 78 phn 2513_004v000 Oct 2012 ...