Task 6: Configuring prot ect ion
phn- 2513_004v000 ( Oct 2012)
6- 55
Before upgrading existing links from unprotected to protected, complete the following
prerequisites:
•
Configure the new CMUs as primary or secondary units by setting the Primary
Secondary Mode attribute.
•
For a new primary CMU, ensure that wireless transmission is disabled by selecting
Mute Transmitter. This prevents possible interference with the existing operational
unit.
•
Attach ‘Primary” or ‘Secondary’ labels as appropriate to the new CMUs.
•
Set Fault Protection Switching to ‘Disabled’. This prevents fault protection switches
occurring during installation.
To configure protection, proceed as follows:
1
Select menu option
System,
Configuration, Protection
. The Protection
Configuration page is displayed (
).
2
If the Transmitter attribute is set to ‘Enabled’, there may be a safety
requirement to disable wireless transmission. If so, select Mute Transmitter.
The Transmitter attribute changes to ‘Muted’.
3
Depending on whether Receive Diversity is required, set the Primary unit
protection attribute to either ‘Hot Standby 1+1’ (
) or ‘Hot Standby
1+1 with Rx Diversity’ (
).
4
Repeat at the Secondary unit (
):
5
Review and update the Protection Configuration attributes (
6
Select
Submit Updated configuration
.
Summary of Contents for PTP 800 Series
Page 1: ...Cambium PTP 800 Series User Guide System Release 800 05 02 ...
Page 40: ...Licensing requirements About This User Guide 10 phn 2513_004v000 Oct 2012 ...
Page 232: ...Limit of liability Chapter 3 Legal information 3 22 phn 2513_004v000 Oct 2012 ...
Page 322: ...Radiation hazard assessm ent Chapter 4 Reference information 4 90 phn 2513_004v000 Oct 2012 ...
Page 428: ...Replacing IRFU components Chapter 5 Installation 5 106 phn 2513_004v000 Oct 2012 ...
Page 630: ...Using recovery mode Chapter 7 Operation 7 78 phn 2513_004v000 Oct 2012 ...