Task 15: Connect ing link t o t he net work
Chapt er 6: Configurat ion and alignm ent
6- 116
phn- 2513_004v000 ( Oct 2012)
Figu r e 1 7 5
Tim e Configurat ion page ( SNTP disabled)
Ta ble 2 4 8
Manual clock at t ribut es
At t r ibu t e
M e a n in g
SNTP State
‘Disabled’ means that the CMU will keep time without
connecting to a networked time server.
Set Time
Current time in hours, minutes and seconds.
Set Date
Current year, month and day.
Time Zone
The time zone offset from Greenwich Mean Time (GMT).
Daylight Saving
‘Disabled’ means that daylight saving adjustments will not
be applied to the time.
‘Enabled’ means that daylight saving adjustments will be
applied to the time, according to local rules.
Setting the real-time clock to synchronize using SNTP
To set the clock to synchronize with a networked time server, select menu option
Management, Time
. The Time Configuration page is displayed. Set the SNTP State
attribute to ‘Enabled’: the SNTP clock attributes are displayed (
). Review and
update the SNTP clock attributes (
), then select
Submit Updated
Configuration
.
Summary of Contents for PTP 800 Series
Page 1: ...Cambium PTP 800 Series User Guide System Release 800 05 02 ...
Page 40: ...Licensing requirements About This User Guide 10 phn 2513_004v000 Oct 2012 ...
Page 232: ...Limit of liability Chapter 3 Legal information 3 22 phn 2513_004v000 Oct 2012 ...
Page 322: ...Radiation hazard assessm ent Chapter 4 Reference information 4 90 phn 2513_004v000 Oct 2012 ...
Page 428: ...Replacing IRFU components Chapter 5 Installation 5 106 phn 2513_004v000 Oct 2012 ...
Page 630: ...Using recovery mode Chapter 7 Operation 7 78 phn 2513_004v000 Oct 2012 ...