Managing alarm s and event s
Chapt er 7: Operat ion
7- 26
phn- 2513_004v000 ( Oct 2012)
SN M P Tr a p n a m e
D e scr ipt ion
Ca u se a n d a ct ion
unitOutOfCalibration
Trap
The unit is out of calibration.
Check the calibration status
and arrange for re-
calibration of the unit.
encryptionEnabledMi
smatchTrap
Encryption has been enabled on
one end of the wireless link but
not the other.
Configuration error in
defining use of encryption
over the wireless link.
sNTPSyncTrap
The PTP 800 has failed to
synchronize its time with the
SNTP server.
If SNTP Sync fails then check
the server settings in the
Remote Management page,
or disable SNTP and set the
time locally. See
on page
wirelessLinkStatusTr
ap
The status of the wireless link
has changed.
This shows the status that
the wireless link has entered.
If the link remains in the
state ‘registering’ or
‘searching’ it is unable to
detect the PTP 800 at the
other end of the link.
This may be due to the unit
at the other end of the link
not being operational, being
incorrectly
configured/aligned or due to
adverse weather conditions.
dataPortConfiguratio
nMismatchTrap
The detection of Ethernet
fragments (runt packets) on the
data Ethernet port when the link
is in full duplex operation.
This is probably due to a
configuration error such as
an auto-negotiation or forced
configuration mismatch.
dataPortDisabledWar
ningTrap
The Administrative Status of the
data Ethernet interface has been
set to disabled.
The Ethernet data port has
been disabled remotely by a
management system.
The physical port continues
to remain operational but no
data is transmitted.
Summary of Contents for PTP 800 Series
Page 1: ...Cambium PTP 800 Series User Guide System Release 800 05 02 ...
Page 40: ...Licensing requirements About This User Guide 10 phn 2513_004v000 Oct 2012 ...
Page 232: ...Limit of liability Chapter 3 Legal information 3 22 phn 2513_004v000 Oct 2012 ...
Page 322: ...Radiation hazard assessm ent Chapter 4 Reference information 4 90 phn 2513_004v000 Oct 2012 ...
Page 428: ...Replacing IRFU components Chapter 5 Installation 5 106 phn 2513_004v000 Oct 2012 ...
Page 630: ...Using recovery mode Chapter 7 Operation 7 78 phn 2513_004v000 Oct 2012 ...