Transmitter status
Transmitter status is indicated by the Transmitter Status attribute in the Status Screen of
the web interface and in Step 6: Antenna Alignment of the Installation Wizard.
The transmitter is muted by default. The transmitter is enabled automatically during
installation in Step 6: Antenna Alignment of the Installation Wizard. The transmitter may
additionally be enabled or muted using the Configuration page of the web interface.
Go to the Status page, or use the Installation Wizard and navigate to Step 6: Antenna
Alignment. Check the Transmitter Status attribute and take action as described in
Table
271
.
Ta ble 2 7 1 Tr a n sm it t e r St a t u s ch e ck s
Tr a n sm it t e r St a t u s
a t t r ibu t e
Act ion
Transmitting
Muted – By User
The Antenna Alignment step of the Install Wizard has
not been completed successfully, or the transmitter
has been muted using the Mute Transmitter button on
the Configuration Page. Restart the Installation
Wizard.
Muted – RFU Configuring
Transmission is disabled while the RFU configuration
is changing. This status will normally exist for no
more than a few seconds.
Muted – RFU Fault
There is a fault in the RFU. Use the Home page to
review the RFU alarms.
Muted – Configuration Error
The RFU is not compatible with the configured radio
license. Restart the Installation Wizard.
Muted - Due to standby
The CMU is the inactive unit of a 1+1 protected end.
Antenna alignment
Repeat the Antenna Alignment procedure as described
Check the receive power from the RSSI connector of the RFU, or from the Receive Power
attribute in Step 6: Antenna Alignment.
If the receive power level is very small or cannot be measured, continue at
Summary of Contents for PTP 800 Series
Page 1: ...Cambium PTP 800 Series User Guide System Release 800 05 02 ...
Page 40: ...Licensing requirements About This User Guide 10 phn 2513_004v000 Oct 2012 ...
Page 232: ...Limit of liability Chapter 3 Legal information 3 22 phn 2513_004v000 Oct 2012 ...
Page 322: ...Radiation hazard assessm ent Chapter 4 Reference information 4 90 phn 2513_004v000 Oct 2012 ...
Page 428: ...Replacing IRFU components Chapter 5 Installation 5 106 phn 2513_004v000 Oct 2012 ...
Page 630: ...Using recovery mode Chapter 7 Operation 7 78 phn 2513_004v000 Oct 2012 ...