PTP 800 Series User Guide
Grounding and light ning prot ect ion
phn- 2513_004v000 ( Oct 2012)
2- 13
Fig u r e 4 4
Grounding and light ning prot ect ion on m ast or t ower ( prot ect ed end)
Protection requirements for the ODU on a high rise building
Applies to ODU deployments only.
If the antenna or ODU is mounted on a high rise building, with cable entry at roof level
(
), then ensure that the installation meets
the following requirements:
•
The antenna and ODU are below the lightning terminals and finials.
•
A grounding conductor is installed around the roof perimeter, to form the main roof
perimeter lightning protection ring.
•
Air terminals are installed along the length of the main roof perimeter lightning
protection ring typically every 6.1m (20ft).