Planning 1+ 0 links
Chapt er 2: Planning considerat ions
2- 30
phn- 2513_004v000 ( Oct 2012)
Planning 1+0 links
When planning 1+0 links, follow the process described in this section.
Concept of a 1+0 link
A 1+0 link is the simplest link to deploy. There is no redundant equipment deployed and so
costs are minimized. The 1+0 link provides no protection in the case of equipment failure.
If a link is very critical to network operation and where a service outage due to equipment
failure cannot be tolerated, consider deploying a 1+1 Hot Standby link.
Antenna, RFU and CMU configurations for 1+0
Select one of the following 1+0 link end configurations:
•
ODU with direct mount antenna (
•
ODU with remote mount antenna (
•
IRFU with remote mount antenna (
Do not install an ODU and an IRFU in the same link, as they cannot interwork.