Equipm ent specificat ions
Chapt er 4: Reference inform at ion
4- 2
phn- 2513_004v000 ( Oct 2012)
Equipment specifications
This section contains specifications of the CMU, RFU and other equipment supplied by
Cambium for PTP 800 installations.
CMU specifications
The PTP 800 CMU (Cambium part number WB3480) conforms to the specifications listed
in
. The CMU and ODU power consumption figures are
Ta ble 7 5
CMU phy sical specificat ions
Ca t e gor y
Spe cifica t ion
Dimensions
Width 18.0 cm (7.1 in), Height 3.5 cm (1.4 in), Depth 22.0 cm (8.7 in)
Weight
1.1 kg (2.4 lbs)
Ta ble 7 6
CMU environm ent al specificat ions
Ca t e gor y
Spe cifica t ion
Temperature
–33°C to 55°C
Humidity
95% non-condensing
Waterproof
IP20
UV Exposure
10 year operational life (UL746C test evidence)
Ta ble 7 7
CMU elect rical specificat ions
Ca t e gor y
Spe cifica t ion
Input voltage
–40.5 V to –60 V
Input voltage withstand
0 V to –72 V
CMU dissipation
21 W
Summary of Contents for PTP 800 Series
Page 1: ...Cambium PTP 800 Series User Guide System Release 800 05 02 ...
Page 40: ...Licensing requirements About This User Guide 10 phn 2513_004v000 Oct 2012 ...
Page 232: ...Limit of liability Chapter 3 Legal information 3 22 phn 2513_004v000 Oct 2012 ...
Page 322: ...Radiation hazard assessm ent Chapter 4 Reference information 4 90 phn 2513_004v000 Oct 2012 ...
Page 428: ...Replacing IRFU components Chapter 5 Installation 5 106 phn 2513_004v000 Oct 2012 ...