PTP 800 Series User Guide
Equipm ent specificat ions
phn- 2513_004v000 ( Oct 2012)
4- 5
ODU specifications
The PTP 800 ODU conforms to the specifications listed in
Ta ble 8 0
ODU physical specificat ions
Ca t e gor y
OD U- A
OD U- B
Dimensions
Diameter 26.7 cm (10.5 in),
Depth 8.9 cm (3.5 in)
Diameter 25.2 cm (9.9 in),
Depth 9.2 cm (3.6 in)
Weight
4.6 kg (10.1 lbs)
3.9 kg (8.6 lbs)
Ta ble 8 1
ODU- A and ODU- B environm ent al specificat ions
Ca t e gor y
Spe cifica t ion
Temperature
–33°C to 55°C (cold start at -45°C)
Humidity
100% condensing
Waterproof
IP67
UV Exposure
10 year operational life (UL746C test evidence)
RSSI output
specifies the voltage measured at the RSSI connector of the ODU for each
combination of received signal level (dBm) and channel separation or bandwidth (MHz).
This table applies to ODU-A and ODU-B.
Ta ble 8 2
RSSI v olt age, r eceived signal level and bandwidt h
RSL
( dBm )
Ch a n n e l se p a r a t ion
7 , 1 3 .7 5 , 1 4 , 2 7 .5 , 2 8 ,
2 9 .6 5 , 5 5 , 5 6 , 6 0 or
8 0 M H z
Ba n dw idt h
1 0 , 2 0 or
4 0 M H z
Ba n dw idt h
3 0 M H z
Ba n dw idt h
5 0 M H z
-20
4.54
4.63
4.71
4.57
-21
4.48
4.57
4.65
4.51
-22
4.41
4.50
4.58
4.44
-23
4.35
4.44
4.52
4.38
-24
4.29
4.38
4.46
4.32
Summary of Contents for PTP 800 Series
Page 1: ...Cambium PTP 800 Series User Guide System Release 800 05 02 ...
Page 40: ...Licensing requirements About This User Guide 10 phn 2513_004v000 Oct 2012 ...
Page 232: ...Limit of liability Chapter 3 Legal information 3 22 phn 2513_004v000 Oct 2012 ...
Page 322: ...Radiation hazard assessm ent Chapter 4 Reference information 4 90 phn 2513_004v000 Oct 2012 ...
Page 428: ...Replacing IRFU components Chapter 5 Installation 5 106 phn 2513_004v000 Oct 2012 ...
Page 630: ...Using recovery mode Chapter 7 Operation 7 78 phn 2513_004v000 Oct 2012 ...