PTP 800 Series User Guide
Equipm ent specificat ions
phn- 2513_004v000 ( Oct 2012)
4- 9
Ta ble 8 4
I RFU elect rical specificat ions
Ca t e gor y
Spe cifica t ion
Input voltage
-48 V dc
Power feed for the RFU transceiver
Direct feed by battery
Power supply inrush current
Compliant to ETS 300 132-2
Ta ble 8 5
I RFU environm ent al specificat ions
Ca t e gor y
Spe cifica t ion
Operational temperature range
-5 to +50 °C
Storage
-45 to + 80 °C
Humidity
Up to 95%, non-condensing
Altitude
0 to 5000 m AMSL
Vibration
EN 300 019-2-3, class 3.2
Transit vibration (packaged equipment) EN 300 019-2-2, class 2.3
Transit shock (packaged equipment)
EN 300 019-2-2, class 2.3
Earthquake
EN 300 019-2-3
Ta ble 8 6
I RFU EMC and safet y com pliance
Ca t e gor y
Spe cifica t ion
Radiated and conducted susceptibility RF Magnetic field: IEC 61000-4-3
Electrical Fast Transient/Burst: IEC 61000-4-4
ESD: IEC 61000-4-2
Radiated emission and conducted
emission
CISPR 22, Class B
FCC 47 CFR Part 15, subpart B, Class B
Canada ICES-003, Class B
Safety requirements
IEC 60950-1 2006, Second Edition
Summary of Contents for PTP 800 Series
Page 1: ...Cambium PTP 800 Series User Guide System Release 800 05 02 ...
Page 40: ...Licensing requirements About This User Guide 10 phn 2513_004v000 Oct 2012 ...
Page 232: ...Limit of liability Chapter 3 Legal information 3 22 phn 2513_004v000 Oct 2012 ...
Page 322: ...Radiation hazard assessm ent Chapter 4 Reference information 4 90 phn 2513_004v000 Oct 2012 ...
Page 428: ...Replacing IRFU components Chapter 5 Installation 5 106 phn 2513_004v000 Oct 2012 ...
Page 630: ...Using recovery mode Chapter 7 Operation 7 78 phn 2513_004v000 Oct 2012 ...