PTP 800 Series User Guide
Replacing I RFU com ponent s
phn- 2513_004v000 ( Oct 2012)
5- 105
Ta ble 2 2 0
RF cable connect ions ( 1+ 1 Tx MHSB / Rx SD exam ple)
#
Pa r t n u m be r
SM A ca b le
con n e ct or fr om
( a n gle d)
SM A ca b le
con n e ct or t o
( st r a igh t )
1
30009399001
Transceiver A
Rx Filter A
2
30009399004
Tx Filter A
RF Switch
3
30009399005
Transceiver A
RF Switch
4
30009399006
Transceiver B
RF Switch
5
30009399001
Transceiver B
Rx Filter B
Remove the RF cable
To remove an RF cable, proceed as follows:
1
Note the Part Number printed on the label of the cable before removal, referring
to
as an example.
2
Using the Standard torque wrench or SMA torque wrench w/right-angle adaptor,
unscrew each connector’s end nut for about three 1/4 turns, enough to reduce
resistance, then continue by hand until free.
Install the new RF cable
To install an RF cable, proceed as follows:
1
Before installing the replacement RF cable, verify that its Part Number matches
exactly that of the discarded cable.
2
Fastening each cable-end nut by hand, start with the angled connector, then
follow by the straight one, as identified in
3
Space permitting,
use the Standard torque wrench set to 0.1 kg•m (9.0 lb
-inch) to
tighten each connector nut. Otherwise, use the SMA torque wrench w/right-angle
adaptor to tighten the SMA connectors.
4
As an alternative, first hand-tighten the RF cable connector nuts to the transceiver
ports – referring to the applicable configuration from
– slide the transceiver in the shelf, then fasten its Captive screws (2)
to secure it in place.
5
As appropriate, use the Standard torque wrench or the SMA torque wrench
w/right-angle adaptor
, set to 0.1 kg•m (9.0 lb
-inch), to tighten all RF cable
connector nuts.
Summary of Contents for PTP 800 Series
Page 1: ...Cambium PTP 800 Series User Guide System Release 800 05 02 ...
Page 40: ...Licensing requirements About This User Guide 10 phn 2513_004v000 Oct 2012 ...
Page 232: ...Limit of liability Chapter 3 Legal information 3 22 phn 2513_004v000 Oct 2012 ...
Page 322: ...Radiation hazard assessm ent Chapter 4 Reference information 4 90 phn 2513_004v000 Oct 2012 ...
Page 428: ...Replacing IRFU components Chapter 5 Installation 5 106 phn 2513_004v000 Oct 2012 ...
Page 630: ...Using recovery mode Chapter 7 Operation 7 78 phn 2513_004v000 Oct 2012 ...