PTP 800 Series User Guide
Task 1: Connect ing t o t he unit
phn- 2513_004v000 ( Oct 2012)
6- 5
6
If the network adaptor supports advanced properties, then configure Ethernet
Speed and Duplex for automatic negotiation. One example, based on a
Broadcom™ adaptor, is shown:
Updating the ARP table
All PTP 800 units are supplied by Cambium with the same default IP address. When the
management PC is connected to a PTP 800 unit, it creates an association between the
default IP address (169.254.1.1) and the MAC address of the PTP 800.
If two or more PTP 800 units are being configured, then remove this association after each
unit has been configured. To remove the association between IP address and MAC address
in the ARP table of the management PC: open a command prompt window on the PC and
enter this command:
arp –d 169.254.1.1
When this address is next used, the PC will connect it with the MAC address of the unit
being configured and update the ARP table with the new association.