Task 1: Connect ing t o t he unit
Chapt er 6: Configurat ion and alignm ent
6- 6
phn- 2513_004v000 ( Oct 2012)
Connecting to the PC and powering up
Connect the PC Ethernet port to the Management port of the CMU using a straight-
through or crossed Cat5e cable. Switch on the CMU power supply. Wait until the CMU
status indicator shows green steady or green slow blink. This normally occurs within 60
seconds from applying power.
Logging into the web interface
If the management PC is connected to another LAN it may need to be configured to not
use proxy servers for this IP address.
To log into the CMU web interface, proceed as follows:
1
Start the web browser from the management PC.
2
Type this IP address of the unit into the address bar: 169.254.1.1
3
Press ENTER. The web interface menu and System Summary page are displayed: