PTP 800 Series User Guide
Using recovery m ode
phn- 2513_004v000 ( Oct 2012)
7- 75
Resetting IP and Ethernet configuration to factory defaults
Perform this task when the CMU is in recovery mode. The purpose of this task is to reset
IP and Ethernet configuration back to factory defaults.
Before starting this task, check that the Recovery Options page is displayed (
To reset IP and Ethernet configuration parameters, proceed as follows:
1
Select
Reset IP & Ethernet Configuration back to factory defaults
. The
Reset Configuration dialog is displayed (
2
Select
OK
. The Recovery Options page is redisplayed with a message indicating
that the configuration has been reset.
3
Select
Reboot
. The Reboot Confirmation dialog is displayed.
4
Select
OK
. The reboot progress message is displayed. On completion, the CMU
restarts.
5
To restore the IP and Ethernet configuration to meet the operator’s
requirements, see
Task 2: Configuring IP and Ethernet interfaces
on page
When the CMU is rebooted after selecting the recovery option
Reset IP & Ethernet
Configuration back to factory defaults
, the IP address remains at its default setting of
169.254.1.1 and the CMU can only be accessed via a direct network connection from the
PC to the management port.
Figu r e 2 0 4
Reset Configurat ion dialog
Summary of Contents for PTP 800 Series
Page 1: ...Cambium PTP 800 Series User Guide System Release 800 05 02 ...
Page 40: ...Licensing requirements About This User Guide 10 phn 2513_004v000 Oct 2012 ...
Page 232: ...Limit of liability Chapter 3 Legal information 3 22 phn 2513_004v000 Oct 2012 ...
Page 322: ...Radiation hazard assessm ent Chapter 4 Reference information 4 90 phn 2513_004v000 Oct 2012 ...
Page 428: ...Replacing IRFU components Chapter 5 Installation 5 106 phn 2513_004v000 Oct 2012 ...
Page 630: ...Using recovery mode Chapter 7 Operation 7 78 phn 2513_004v000 Oct 2012 ...