Test ing prot ect ion swit chover
Chapt er 8: Troubleshoot ing
8- 14
phn- 2513_004v000 ( Oct 2012)
Check the status of the wireless interface
Check the status of the wireless interface, see
If the wireless link quality has been affected by adverse weather it is likely that the
secondary unit will not be able to provide a service either, particularly if an asymmetric
coupler has been used or the secondary unit is providing antenna protection with a less
powerful antenna.
Check the link protection cable
Check the link protection cable is connected as described in
Force a protection switchover
Consider manually initiating a protection switchover as described in
, provided the link planning indicates that the units have the
capability of operating a link of satisfactory quality.
This particularly applies where asymmetric couplers have been used, or a secondary
antenna of lower power.
Check the configuration of the active and inactive units
Check that the active and inactive units have a compatible configuration.
They must be configured to have:
•
The same link parameters;
•
The same radio licence parameters;
•
The same radio parameters;
•
The same encryption parameters;
•
The same management and protection options;
•
The same data connectivity parameters
They must be configured to have different IP addresses and different primary/secondary
attributes.
Summary of Contents for PTP 800 Series
Page 1: ...Cambium PTP 800 Series User Guide System Release 800 05 02 ...
Page 40: ...Licensing requirements About This User Guide 10 phn 2513_004v000 Oct 2012 ...
Page 232: ...Limit of liability Chapter 3 Legal information 3 22 phn 2513_004v000 Oct 2012 ...
Page 322: ...Radiation hazard assessm ent Chapter 4 Reference information 4 90 phn 2513_004v000 Oct 2012 ...
Page 428: ...Replacing IRFU components Chapter 5 Installation 5 106 phn 2513_004v000 Oct 2012 ...
Page 630: ...Using recovery mode Chapter 7 Operation 7 78 phn 2513_004v000 Oct 2012 ...