2
Levelling the Camera using the RPS-180 level disc
Figure 3 RPS-180 Horizontal plane adjustment
The RPS-180 level head features an horizontal plane adjustment of +/- 5
degrees. To adjust the horizontal plane position, use the two setscrews
C1 and C2 (Allen key 4mm).
ATTENTION:
for the adjustment always loosen one of the screws and
then tighten the other. When tightening the setscrews,
don’t overt
-
tighten (fixed = fixed).
To adjust the level counter clockwise , loosen C2. until the camera is
levelled, then tighten screw C1.
To adjust the level clockwise , fully loosen C1 then tighten screw C2, until
the camera is levelled, then tighten C1.