Changing the RPS-180 QR clamp orientation 

 

 

 

The orientation of the RPS-180 QR clamp (D.) can be changed from 
horizontal (default) to vertical. A vertical QR clamp position may be 
desired when using a rail based Repro camera like the ACTUS-Repro. To 
change the QR clamp orientation remove bolts F using a 5mm Allen key. 
Rotate the QR clamp D counter clockwise so the clamp knob E is pointing 
towards the right (seen from front).    

 

Figure 5 RPS-180 QR Clamp orientation 

 

Summary of Contents for RPS-180 Levelling unit Pro

Page 1: ...RPS 180 Levelling unit Pro For Cambo RPS cross arms INSTRUCTION MANUAL EN Please read this manual carefully before using the RPS 180 ...

Page 2: ...ambo quick release clamp Arca compatible E Quick release clamp knob F Quick release position screws 2x hexagon bolt Allen key 5mm G Cross Arm positioning slot H RPS 180 Positioning screws Figure 2 RPS 180 Placement To fix the RPS 180 to the RPS cross arm place the RPS 180 positioning screws H in the RSP cross arm slot G and fix the RPS 180 into position by tightening Camera plate knob A firmly ...

Page 3: ...ion use the two setscrews C1 and C2 Allen key 4mm ATTENTION for the adjustment always loosen one of the screws and then tighten the other When tightening the setscrews don t overt tighten fixed fixed To adjust the level counter clockwise loosen C2 until the camera is levelled then tighten screw C1 To adjust the level clockwise fully loosen C1 then tighten screw C2 until the camera is levelled then...

Page 4: ... adjustment To adjust the vertical plane please use the level screws B Screw B2 and B3 tilts and swings the camera by tightening or loosening the screws B2 and B3 Note only in exceptional circumstances screw B1 is used this is only then the adjustments of B2 and B3 are not sufficient ...

Page 5: ...o vertical A vertical QR clamp position may be desired when using a rail based Repro camera like the ACTUS Repro To change the QR clamp orientation remove bolts F using a 5mm Allen key Rotate the QR clamp D counter clockwise so the clamp knob E is pointing towards the right seen from front Figure 5 RPS 180 QR Clamp orientation ...

Reviews: