background image

R

L

R

L

R

L

IR1

IR2

IR3

IR4

Keypad 1

Keypad 2

Multi-Room

IR Emitter

In

Trigger

In

Out/Thru

In

Out

Left

Right

Re

c Out 2

Sub Out

Re

c Out 1

Rec

 In

Input 7

Input 6

Input 5

Input 4

Input 3

Input 2

Input 1

Rec Out 2

Rec Out 1

Rec In

Input 7

Input 6

Input 5

Input 4

Input 3

Input 2

Input 1

(Unbalanced)

(Unbalanced)

Pre Out

Pre Out

Left

Right

Left

Right

Balanced Pre Out

Left

Right

RS232C

Control Bus

PSU

In

International Patent Pending

LeisureTech Electronics Pty Ltd

GND

Power AC

On

Off

Power

azur 840E Pre-Amplifier

Power Rating

:

  230V AC ~ 50Hz

Max Power Consumption

:

  36W

Designed in London, England

Flat / 200Hz L.P.

Manufactured
in an ISO9001

approved facility

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference; 2) This device must accept any interference, including interference that may cause undesired operation.

Input 2 Balanced Audio

Balanced

Unbalanced

Balanced

Unbalanced

Input 1 Balanced Audio

Input 1

Input 2

GND

CAUTION

Risk of electric

shock.

Do not open.

AVIS

Risque de choc

electrique.

Ne pas ouvrir.

ACHTUNG

Vorm öffnen
des gerätes.

Netzstecker ziehen.

R

L

www.cambridge-audio.com

840E

azur

ENGLISH

5

Rear panel connections

Power On/Off

Switches the unit on and off.

AC power socket

Once you have completed all connections to the unit, plug the AC power
cable into an appropriate mains socket then switch on. Your unit is now
ready for use.

Trigger In, Out/Thru

For Custom Install use, the 840E can be turned on and off (i.e. brought
in and out of Standby mode) by the presence of 5-12V DC at the Trigger
input. A trigger input will also produce an internally generated 12V DC
trigger output at the Output/Thru connection. Turning the 840E on from
the remote/front panel also produces a 12V DC trigger output at the
Output/Thru connection. This can be used to turn on/Standby a
connected 840W power amplifier if desired. Refer to the ‘Power syncing’
section of this manual for more information.

IR (Infra-Red) Emitter In

Allows modulated IR commands from multi-room systems or IR repeater
systems to be received by the unit. Commands received here are not
looped out of the Control Bus. Refer to the ‘Custom installation’ section
of this manual for more information. 

Control Bus

In - Allows un-modulated commands from multi-room systems or other
components to be received by the unit.

Out - Loop out for Control Bus commands to another unit. 

Also allows the 840E to turn on/off some Cambridge Audio units,
including the matching 840W power amplifier. Refer to the ‘Power
syncing’ section of this manual for more information.

RS232C

The RS232C port allows external serial control of the 840E for custom
install use. A full command set is available on the Cambridge Audio
website at www.cambridge-audio.com. This port can also be used by
Cambridge Audio service personnel for software updates.

A-BUS™ Ready / Incognito Ready™
multi-room outputs

PSU In - Connect an Incognito PS5 to supply power to the connected
multi-room keypads/speakers.

Keypad 1/2 - Connect one or two Incognito A-BUS KP10 keypads (or
other A-BUS compatible keypads) using CAT5/5e cable. Incognito AS10
Active Ceiling Speakers can also be connected here.

IR - Four IR outputs for remote control of source equipment.

Please refer to the ‘Multi-Room’ section of this manual for more
information on connections and set-ups.

Input 1/2 Balanced Audio

Inputs 1 and 2 feature either unbalanced (phono/RCA) or balanced
(XLR) connections. Either type may be used but not both at the same
time. The balanced connection is the higher quality option and can
reject noise and interference in the cable when used with other
equipment that supports this function. An XLR connector is wired Pin 1
- Ground; Pin 2 - Hot (in-phase); Pin 3 - Cold (phase-inverted).

Use the Balanced/Unbalanced switch (Item 9) to select the connection
type you wish to use. The unused input does not require to be
terminated.

Input 1/Input 2 Balanced/Unbalanced switch

Use to select the connection type for Input 1/Input 2.

Inputs 1-7

These inputs are suitable for any 'line level' source equipment such as
CD players, DAB or FM/AM tuners etc.

Note: These inputs are for analog audio signals only. They should not be
connected to the digital output of a CD player or any other digital device.

Rec In (Input 8)

Connect to the output sockets of a Tape/MD player or other devices that
support recording.

Rec Out 1/2

Connect to the input sockets of your recording device.

Flat/200Hz LP switch

The 840E features a Sub output that is a separate mono mix created
from the main pre-amp outputs. This output can have either a ‘Flat’ (i.e.
full range, unfiltered) frequency response or a 200Hz Low Pass filter can
be applied. Most Subwoofers feature built in Low Pass filtering and ‘Flat’
is usually the best setting. This setting does not affect the main outputs
which are always full-range.

Sub Out

Connect to the input on an active subwoofer if required.

Balanced Pre Out

For connection to the balanced inputs of a power amplifier that support
this type of connection.

Pre Out

For connection to the unbalanced inputs of a power amplifier.

1

1

2

3

4

6

7

5

9

2

3

8

5

6

9

11

12

13

14

15

16

4

10

7

10

11

12

15

13

14

16

8

Summary of Contents for Azur 840E

Page 1: ...Pre Amplifier User s manual 2 ENGLISH 840E azur ...

Page 2: ...xposed to dripping or splashing water or other liquids No objects filled with liquid such as vases shall be placed on the unit The lightning flash with the arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of un insulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons...

Page 3: ...n warranty service please contact the Cambridge Audio authorised dealer from which you purchased this product If your dealer is not equipped to perform the repair of your Cambridge Audio product it can be returned by your dealer to Cambridge Audio or an authorised Cambridge Audio service agent You will need to ship this product in either its original packaging or packaging affording an equal degre...

Page 4: ...d to the same exacting standards as this pre amplifier Your dealer can also supply excellent quality Cambridge Audio interconnects to ensure your system realises its full potential Thank you for taking the time to read this manual we do recommend you keep it for future reference Matthew Bramble Cambridge Audio Technical Director and the 840E 840W design team Contents Introduction Important safety ...

Page 5: ...units including the matching 840W power amplifier Refer to the Power syncing section of this manual for more information RS232C The RS232C port allows external serial control of the 840E for custom install use A full command set is available on the Cambridge Audio website at www cambridge audio com This port can also be used by Cambridge Audio service personnel for software updates A BUS Ready Inc...

Page 6: ... input selection button to select the source component that you wish to listen to highlighted by a solid circle on the display The signal selected is also fed to the Rec Out sockets so that it may be recorded The input should not be changed whilst recording Display LCD used to control the 840E Please refer to the Operating instructions and Pre amplifier setup section of this manual for more inform...

Page 7: ...ght Skip Press once to skip forward by one track on the CD Press and hold to skip forwards through tracks Left Skip Press once to skip backward by one track on the CD Press and hold to skip backwards through tracks Search Press and hold to search within the selected track Right button to fast forward left button to rewind Repeat Random Remain Refer to the Operating instructions section of your CD ...

Page 8: ... com Figure 1 Unbalanced input Figure 2 Balanced input Phono RCA 840E 840C XLR 840E 840C Power syncing On Standby control When going in out of Standby mode the Azur 840E pre amplifier can if desired automatically control the 840W when connected via the Control Bus sockets the Control Bus sockets are colour coded orange on the rear panels of compatible Azur models For this feature to work the units...

Page 9: ...t connections Unbalanced The 840E features both balanced XLR and unbalanced RCA Phono output connections For the best quality we recommend you use the balanced output with power amplifiers that feature this connection such as our own 840W Class XD power amplifier The diagram below shows the 840E pre amplifier connected to an Azur 840W power amplifier and a pair of loudspeakers When using unbalance...

Page 10: ...open AVIS Risque de choc electrique Ne pas ouvrir ACHTUNG Vorm öffnen des gerätes Netzstecker ziehen On Off Loop Output Input Balanced Audio Right Unbalanced Audio Right Input Loop Output Input Loop Output Out Control Bus Trigger IR Emitter In Out Thru In In Loop Output Input Balanced Audio Left Unbalanced Audio Left azur 840W Class XDTM Power Amplifier Power Rating 230V AC 50Hz Max Power Consumpt...

Page 11: ...ating that they are active and direct mode is Off The 840E stores whether Direct mode is on or off for each input individually For example it is possible to have the tone controls automatically active for the Tuner source but not the CD source Pre amplifier setup The 840E features many advanced settings that allow its use to be customised to user preference The inputs can be named to reflect the a...

Page 12: ...CSA STD C22 2 No 60065 03 3098092 C SL L L SW SR R R Power AC On Off Power SCART Composite RGB Stereo Audio In Out www cambridge audio com Toslink Optical S P DIF Co axial azur 540D V2 0 DVD Player Power Rating 100 240V AC 50 60Hz Max Power Consumption 25W Designed in London England Composite S Video Cr Pr Cb Pb Y Component Video Out 5 1 Channel Audio Out This product complies with DHHS rules 21 C...

Page 13: ... 1600W www cambridge audio com Designed in London England Power AC Please ensure that loudspeaker terminals are fully tightened Veuillez s assurer que les bornes de l enceinte sont entièrement serrées Stereo Mono Bi Amp Bridged Loudspeaker Terminals Right Impedance 4 8 ohms Bridged Bridged only Please ensure that loudspeaker terminals are fully tightened Veuillez s assurer que les bornes de l ence...

Page 14: ...h means the keypads can operate independently of the amplifier in terms of volume bass treble etc be independently turned on and off and can also listen to a different source from that which is currently selected on the amplifier However both keypads can only listen to the same source A BUS is a standard that allows compatibility between different manufacturers equipment so A BUS compatible keypad...

Page 15: ...ut Control Bus There is no power Ensure the AC power cord is connected securely Ensure the plug is fully inserted into the wall socket and is switched on Check fuse in the mains plug or adaptor There is no sound Make sure the unit is not in Standby mode Check that source component is properly connected Check that Input 8 Rec In is not switched on unless a tape input is required Check that your spe...

Page 16: ...1 Cambridge Audio is a brand of Audio Partnership Plc Registered Office Gallery Court Hankey Place London SE1 4BB United Kingdom Registered in England No 2953313 www cambridge audio com 2007 Cambridge Audio Ltd ...