8
840E
840W
Bi-wired stereo connections
The diagram below shows the 840W connected to an 840E bi-wired to
a pair of loudspeakers.
IMPORTANT! The metal strip connecting the low-frequency terminals to
the high-frequency terminals must be removed for a bi-wiring system.
Note:
In this configuration the 840W must be set to Stereo mode.
On
Off
Loop Output
Input
Balanced Audio - Right
Unbalanced
Audio - Right
Input
Loop Output
Input
Loop Output
Out
Control Bus
Trigger
IR Emitter
In
Out/Thru
In
In
Loop Output
Input
Balanced Audio - Left
Unbalanced
Audio - Left
azur 840W Class XD
TM
Power Amplifier
Power Rating
:
220 - 230V AC ~ 50/60Hz
Max Power Consumption
:
2400W
www.cambridge-audio.com
Designed in London, England
Power AC
Please ensure that loudspeaker terminals are fully tightened
Veuillez s'assurer que les bornes de l'enceinte sont entièrement serrées
Stereo
Mono
Bi-Amp
Bridged
Loudspeaker Terminals - Right
Impedance 4 - 8 ohms
Bridged
Bridged
only!
Please ensure that loudspeaker terminals are fully tightened
Veuillez s'assurer que les bornes de l'enceinte sont entièrement serrées
Loudspeaker Terminals - Left
Impedance 4 - 8 ohms
Bridged
only!
Manufactured in an ISO9001 approved facility
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference
2) This device must accept any interference, including interference that may cause undesired operation
N1863
AЯ
46
1 = Ground
2 =
3 =
In
Loop
1 = Ground
2 =
3 =
In
Loop
Balanced
Balanced
Unbalanced
Left
Input Type
Balanced
Unbalanced
Right
Input Type
IMPORTANT!
Only change modes
when unit is off.
Refer to Manual for
more information.
Use Left Input for
Bridged
/ Bi-Amp
operation.
Mono Mode
Class 2 Wiring
Class 2 Wiring
CAUTION
Risk of electric
shock.
Do not open.
AVIS
Risque de choc
electrique.
Ne pas ouvrir.
ACHTUNG
Vorm öffnen
des gerätes.
Netzstecker ziehen.
R
L
R
L
R
L
IR1
IR2
IR3
IR4
Keypad 1
Keypad 2
Multi-Room
IR Emitter
In
Trigger
In
Out/Thru
In
Out
Left
Right
Re
c Out 2
Sub Out
Re
c Out 1
Rec
In
Input 7
Input 6
Input 5
Input 4
Input 3
Input 2
Input 1
Rec Out 2
Rec Out 1
Rec In
Input 7
Input 6
Input 5
Input 4
Input 3
Input 2
Input 1
(Unbalanced)
(Unbalanced)
Pre Out
Pre Out
Left
Right
Balanced Pre Out
Left
Right
RS232C
Control Bus
PSU
In
International Patent Pending
LeisureTech Electronics Pty Ltd
GND
Power AC
On
Off
Power
azur 840E Pre-Amplifier
Power Rating
:
220 - 230V AC ~ 50/60Hz
Max Power Consumption
:
36W
Designed in London, England
Flat / 200Hz L.P.
Manufactured
in an ISO9001
approved facility
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference; 2) This device must accept any interference, including interference that may cause undesired operation.
Input 2 Balanced Audio
Balanced
Unbalanced
Balanced
Unbalanced
Input 1 Balanced Audio
Input 1
Input 2
GND
CAUTION
Risk of electric
shock.
Do not open.
AVIS
Risque de choc
electrique.
Ne pas ouvrir.
ACHTUNG
Vorm öffnen
des gerätes.
Netzstecker ziehen.
R
L
www.cambridge-audio.com
Advanced connections
As well as normal single-wired stereo operation (whether balanced or unbalanced), several other modes of operation are possible; Bi-wired Stereo, Bi-
Amped Mono and Bridged Mono and others.
In all of the following examples either balanced or unbalanced connections can be used, the principle is exactly the same for each type of connection.
For simplicity, we will show only the balanced connections in each example.
Power syncing (On/Standby control)
When going in/out of Standby mode the Azur 840E pre-amplifier can (if
desired) automatically control the 840W when connected via the Control
Bus sockets (the Control Bus sockets are colour-coded orange on the
rear panels of compatible Azur models). For this feature to work the
units must be connected together by RCA/phono leads. No further setup
is necessary.
Connect the Control Bus Out from the 840E to the Control Bus In on the
840W. Continue the chain to other Azur models if it is required to sync
more units (refer to the 840E’s own manual for more information as this
requires some setup).
R
L
R
L
R
L
IR1
IR2
IR3
IR4
Keypad 1
Keypad 2
Multi-Room
IR Emitter
In
Trigger
In
Out/Thru
In
Out
Left
Right
Re
c Out 2
Sub Out
Re
c Out 1
Rec
In
Input 7
Input 6
Input 5
Input 4
Input 3
Input 2
Input 1
Rec Out 2
Rec Out 1
Rec In
Input 7
Input 6
Input 5
Input 4
Input 3
Input 2
Input 1
(Unbalanced)
(Unbalanced)
Pre Out
Pre Out
Left
Right
Balanced Pre Out
Left
Right
RS232C
Control Bus
PSU
In
International Patent Pending
LeisureTech Electronics Pty Ltd
GND
Power AC
On
Off
Power
azur 840E Pre-Amplifier
Power Rating
:
230V AC ~ 50Hz
Max Power Consumption
:
36W
Designed in London, England
Flat / 200Hz L.P.
Manufactured
in an ISO9001
approved facility
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference; 2) This device must accept any interference, including interference that may cause undesired operation.
Input 2 Balanced Audio
Balanced
Unbalanced
Balanced
Unbalanced
Input 1 Balanced Audio
Input 1
Input 2
GND
CAUTION
Risk of electric
shock.
Do not open.
AVIS
Risque de choc
electrique.
Ne pas ouvrir.
ACHTUNG
Vorm öffnen
des gerätes.
Netzstecker ziehen.
R
L
www.cambridge-audio.com
On
Off
Loop Output
Input
Balanced Audio - Right
Unbalanced
Audio - Right
Input
Loop Output
Input
Loop Output
Out
Control Bus
Trigger
IR Emitter
In
Out/Thru
In
In
Loop Output
Input
Balanced Audio - Left
Unbalanced
Audio - Left
azur 840W Class XD
TM
Power Amplifier
Power Rating
:
230V AC ~ 50Hz
Max Power Consumption
:
1600W
www.cambridge-audio.com
Designed in London, England
Power AC
Please ensure that loudspeaker terminals are fully tightened
Veuillez s'assurer que les bornes de l'enceinte sont entièrement serrées
Stereo
Mono
Bi-Amp
Bridged
Loudspeaker Terminals - Right
Impedance 4 - 8 ohms
Bridged
Bridged
only!
Please ensure that loudspeaker terminals are fully tightened
Veuillez s'assurer que les bornes de l'enceinte sont entièrement serrées
Loudspeaker Terminals - Left
Impedance 4 - 8 ohms
Bridged
only!
Manufactured in an ISO9001 approved facility
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference
2) This device must accept any interference, including interference that may cause undesired operation
N1863
AЯ
46
1 = Ground
2 =
3 =
In
Loop
1 = Ground
2 =
3 =
In
Loop
Balanced
Balanced
Unbalanced
Left
Input Type
Balanced
Unbalanced
Right
Input Type
IMPORTANT!
Only change modes
when unit is off.
Refer to Manual for
more information.
Use Left Input for
Bridged
/ Bi-Amp
operation.
Mono Mode
Class 2 Wiring
Class 2 Wiring
CAUTION
Risk of electric
shock.
Do not open.
AVIS
Risque de choc
electrique.
Ne pas ouvrir.
ACHTUNG
Vorm öffnen
des gerätes.
Netzstecker ziehen.
Note: The 840E features a Trigger Out which can alternatively be used
to control the 840W’s Standby/On status if desired. Again, the
procedure is simply to connect the two units together (using a 3.5mm to
3.5mm mono mini-jack lead in this case).
Control Bus is the recommended method when using an 840E and other
Cambridge Audio equipment with Control Bus In/Out.
Trigger In/Out can be useful if the 840W (and indeed 840E) is desired
to be controlled by other equipment that features trigger outputs
(Custom install and/or Multi-Room Systems etc).
840W
840E