32"
26 14 "
26 14 "
29 34 "
14"
6 12 " MIN CLEARANCE
10 14 "
28 14 "
12 34 "
TO BE LOCATED WITHIN 20ft OF
ELEVATOR HOISTWAY
FOR LONGER DISTANCES CONSULT
CAMBRIDGE ELEVATING
3.0 or 5.0 H.P. 220V/1/60Hz DRIVE MOTOR
ACCESS REQUIRED TO TOP OF UNIT
FOR OIL FILLING AND PIPING
DISCONNECTS SUPPLIED BY C.E.I. ON
MAIN ELEVATOR CONTROL PANEL
HYDRAULIC OIL:
32 WEIGHT PREMIUM
CAPACITY: 75L / 20 US Ga
HYDRAULIC LINE TO
CYLINDER
SHUT OFF
VALVE
FILLER BREATHER
FOR OIL
28"
30"
28 14 "
13"
PLYWOOD
MAIN ELEVATOR
CONTROLLER PANEL
LIGHTING
DISCONNECT
120VAC
15 AMP
NEMA 5-15P
PLUG
PUMP
DISCONNECT
240VAC
30 AMP
NEMA 14-30P
PLUG
8 12 "
HYDRAULIC
POWER UNIT
BES3 RESIDENTIAL PUMP
CONTROLLER DETAILS
WIRE GAUGE AS
PER LOCAL CODE
REQUIREMENTS
USUALLY MOUNTED IN
MECHANICAL ROOM
ON WALL
WITHIN 6' OF
HYDRAULIC POWER UNIT
OR TO STRUTS MOUNTED
ON REAR OF PUMP TANK
OUTLETS TO BE
SUPPLIED BY G.C
WITHIN 36"
OF THE
CONTROLLER ON THE
RIGHT SIDE.
REQUIRES:
*
NEMA 5-15
OUTLET AT 60" HIGH
*
NEMA 14-30
OUTLET AT 48" HIGH
WWW.CAMBRIDGEELEVATING.COM
CAMBRIDGE, ONTARIO
THIS DRAWING AND THE INFORMATION IT CONTAINS ARE PROPRIETARY TO
CAMBRIDGE ELEVATING INC. THIS DOCUMENT MUST NOT BE DUPLICATED,
OR ITS CONTENTS USED OR DISCLOSED (IN WHOLE OR IN PART) WITHOUT
THE WRITTEN PERMISSION FROM CAMBRIDGE ELEVATING INC.
1261 INDUSTRIAL RD
Summary of Contents for Cambrian