Cambridge Elevating Inc. Residential Elevator Specifications 

PART 1 – GENERAL 

1.1 Summary 

This specification describes the planning, labor, and materials required to install a private residence home 

elevator manufactured by Cambridge Elevating Inc.  

1.2 System Description 

A  private  residence  1:2  roped  hydraulic  elevator  complete  with  guide  rail  system,  hydraulic  power  unit, 

control  panel,  switches,  wiring  and  any  parts  necessary  to  properly  install  the  elevator  to  meet 

performance, safety and code standards. 

1.3 Quality Assurance 

The elevator shall be designed, tested and installed in compliance with all applicable regulations and in 

accordance with ASME A17.1/CSA B44.0 standards. Elevator may be subject to state, local and city approval 

prior to installation and subject to inspection after installation.  

1.4 Applicable Codes and Standards 

1.4.1  ASME A17.1/CSA B44-1

3

, Section 5.3 

Private Residence Elevators

 

1.4.2  ASME A17.5/CSA B44.1, 

Elevator and Escalator Electrical Equipment

 

1.4.3  ICC/ANSI A117.1-1998, 

Accessible and Usable Buildings and Facilities

 

1.4.4  NFPA 70-1999, 

National Electric Code

 

1.4.5  ADAAG, 

Americans with Disabilities Act Accessibility Guidelines

 

PART 2 – PREPARATORY WORK BY OTHERS 

2.1 Hoistway 

Provide an enclosed, plumb and square hoistway with smooth interior surfaces. Provide fascias or furring 

of hoistway interior where required. Provide correct door RSO and headers as described on site specific 

layout drawings. Construction of hoistway, including rail support wall and pit floor must withstand all loads 

as described on site specific layout drawings.  Rail wall construction must provide adequate anchoring 

means for guide rail support system as described in hoistway detail drawings. 

2.2 Machine Room 

Provide a machine room as required by applicable codes and standards. 

2.3 Electrical 

2.3.1 General Contractor to provide one 220 VAC, 60 Hz, 30 Amp single phase power source in the machine 

room. 230 VAC disconnect provided by Cambridge Elevating. 

2.3.2 General Contractor to provide one 120VAC, 60 Hz, 15 Amp power source and disconnect in the 

machine room.  120 VAC disconnect provided by Cambridge Elevating. 

Summary of Contents for Cambrian

Page 1: ...Residential Elevator Design Guide All Models Elmira Heritage Cambrian 1261 Industrial Rd Cambridge ON N3H 4W3 p 1 800 265 3579 p 519 653 4222 fl 519 653 9927 www CambridgeElevating com ...

Page 2: ...ruction Wood Stud Wall Hoistway Elevation Overhead Requirements Pit Details Machine Room Details General Layout Machine Room Details Controller Pump Details Cambrian Landing Frame Details Elevation Cambrian Landing Frame Details Layout Drawings Elmira Model Cab Hoistway Size Layout Drawings Heritage Model Cab Hoistway Size Layout Drawings Cambrian Model Cab Hoistway Size Layout Elevator Specificat...

Page 3: ... to change without notice Planning for a Cambridge Elevating Home Elevator The following planning procedure is strongly recommended 1 Determine the customer s intended use 2 Determine the customer s desired convenience level with respect to model type Elmira swing landing door with manual or automatic accordion cab gate Heritage swing landing door with automatic sliding cab door panels Cambrian au...

Page 4: ...Cambrian Landing Frame Details see page 12 Provide required rough openings at each hoistway landing as per elevator manufacturer s engineered drawings Provide sufficient machine room area suitable to contain hydraulic power unit and elevator controller disconnect based on elevator manufacturer s engineered drawings Provide telephone connection to outside line for integration into elevator controll...

Page 5: ...ige or s s Automatic sliding landing door panels beige or s s Controls Microprocessor controller with relays for basic operation Fully automatic operation Automatic timed cab lighting Stainless steel car operating panel COP telephone box and hall call stations Dual illuminated hall call station push buttons and position indicating push buttons on COP Emergency stop switch on COP LED dot matrix Dig...

Page 6: ...tructure must sustain a chain hoist for hoisting elevator materials to the top of the hoistway during installation A structural engineer must ensure that building and hoistway can safely support all loads imposed by the elevator equipment The drawings contained herein have been prepared using engineering principles and the design loads that are applied by the rails to the wall However the details ...

Page 7: ...WO 2 x 12 INSIDE TWO 2 x 6 2x6s SCREWED TO 2x12s EVERY 6 WITH 10x3 1 2 WOOD SCREWS CHANNELS AND MIDDLE STUDS BETWEEN FLOORS FULL HEIGHT OF HOISTWAY MIDDLE STUDS THREE 2 x 6 3 4 PLYWOOD DOOR WALL CAMBRIDGE ELEVATING IS NOT RESPONSIBLE FOR THE STRUCTURAL DESIGN OF THE BUILDING AND ITS ABILITY TO SUPPORT THE ELEVATOR LOADS AND OR REACTIONS R1 720LBS R2 225LBS R3 720LBS WWW CAMBRIDGEELEVATING COM CAMB...

Page 8: ......

Page 9: ... PIT FLOOR TO BE MADE OF MINIMUM 15MPa CONCRETE 4 0 MINIMUM 12 FOR HERITAGE OR CAMBRIAN 8 MIN ELMIRA SECTION A A FINISH BASEMENT WWW CAMBRIDGEELEVATING COM CAMBRIDGE ONTARIO THIS DRAWING AND THE INFORMATION IT CONTAINS ARE PROPRIETARY TO CAMBRIDGE ELEVATING INC THIS DOCUMENT MUST NOT BE DUPLICATED OR ITS CONTENTS USED OR DISCLOSED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION FROM CAMBRIDGE E...

Page 10: ...rdance with all codes and regulations A 220 VAC 60 Hz 30 Amp single phase power source in the machine room to be provided A 115 VAC 60 Hz 15 Amp single phase power source in the machine room to be provided A telephone line circuit to be provided if required This circuit must be connected to an outside line ...

Page 11: ...EMA 5 15P PLUG PUMP DISCONNECT 240VAC 30 AMP NEMA 14 30P PLUG 8 1 2 HYDRAULIC POWER UNIT BES3 RESIDENTIAL PUMP CONTROLLER DETAILS WIRE GAUGE AS PER LOCAL CODE REQUIREMENTS USUALLY MOUNTED IN MECHANICAL ROOM ON WALL WITHIN 6 OF HYDRAULIC POWER UNIT OR TO STRUTS MOUNTED ON REAR OF PUMP TANK OUTLETS TO BE SUPPLIED BY G C WITHIN 36 OF THE CONTROLLER ON THE RIGHT SIDE REQUIRES NEMA 5 15 OUTLET AT 60 HI...

Page 12: ...ng to leave door walls wide open for installation Landing door jambs and header fit within rough stud opening Landing door operating mechanism door frames and sill hang in hoistway attached to inside wall of hoistway using brackets Drawing below depicts view from landing looking into elevator hoistway rails support on right wall ...

Page 13: ...www CambridgeElevating com August 2017 13 Cambrian Landing Frame Details Layout It is the recommendation of Cambridge Elevating to leave door walls wide open for installation ...

Page 14: ...66 25 31 31 25 40 x 48 58 x 54 25 35 26 75 40 x 54 58 x 60 25 35 28 25 Please note dimensions remain for mirrored configurations TYPE 1 INLINE Cab Size Centerlines Hoistway Size Width x Depth Landing Door Rail Wall 36 x 48 54 x 50 5 31 24 25 36 x 54 54 x 56 5 31 27 25 36 x 60 54 x 62 5 31 31 25 40 x 48 58 x 50 5 35 24 25 40 x 54 58 x 56 5 35 27 25 Please note dimensions remain for mirrored configu...

Page 15: ...7 48 x 42 58 x 56 25 35 29 54 x 48 64 x 62 25 41 32 60 x 48 70 x 62 25 47 35 Please note dimensions remain for mirrored configurations TYPE 5 INLINE Cab Size Hoistway Size Centerlines Width x Depth Landing Door Rail Wall 36 x 48 51 75 x 54 25 28 5 25 25 40 x 60 55 75 x 66 25 33 31 25 48 x 48 63 75 x 54 25 40 5 25 25 48 x 60 63 75 x 66 25 40 5 31 25 Please note dimensions remain for mirrored config...

Page 16: ... 54 x 70 5 32 75 34 0625 40 x 54 3 panel doors 58 x 62 5 34 75 31 0625 Please note dimensions remain for mirrored configurations TYPE 1 INLINE Cab Size Hoistway Size Centerlines Width x Depth Landing Door Rail Wall 44 x 48 2 panel doors 62 x 58 5 38 75 29 25 36 x 48 3 panel doors 54 x 59 75 32 75 29 875 36 x 60 3 panel doors 54 x 71 75 32 75 35 875 40 x 54 3 panel doors 58 x 65 75 34 75 32 875 Ple...

Page 17: ...oors 54 x 75 25 32 75 39 40 x 54 3 panel doors 58 x 69 25 34 75 36 Please note dimensions remain for mirrored configurations TYPE 1 INLINE Cab Size Hoistway Size Centerlines Width x Depth Landing Door Rail Wall 44 x 48 2 panel doors 62 x 65 75 38 75 32 75 36 x 48 3 panel doors 54 x 68 5 32 75 34 25 36 x 60 3 panel doors 54 x 80 5 32 75 40 25 40 x 54 3 panel doors 58 x 74 5 34 75 37 25 Please note ...

Page 18: ...or and Escalator Electrical Equipment 1 4 3 ICC ANSI A117 1 1998 Accessible and Usable Buildings and Facilities 1 4 4 NFPA 70 1999 National Electric Code 1 4 5 ADAAG Americans with Disabilities Act Accessibility Guidelines PART 2 PREPARATORY WORK BY OTHERS 2 1 Hoistway Provide an enclosed plumb and square hoistway with smooth interior surfaces Provide fascias or furring of hoistway interior where ...

Page 19: ...able please consult your authorized dealer or CE sales representative A minimum cab width of 44 is required for 2 speed panel doors 4 2 1 2 Cab Configuration Inline enter exit same side 90 degree or straight thru layouts available 4 2 1 3 Cab Construction Metal bracket and or tubular frame structure with melamine veneer stainless steel or laminate finish panels Ceiling white melamine or to match w...

Page 20: ...ower outages 4 2 4 Cylinder Single stage jack with line rupture valve 750 psi working pressure 4 2 5 Ropes Two 3 8 diameter 9 x 17 wire ropes 4 2 6 Guide rail Dual 8 lb steel modular T rail system 4 2 7 Car Sling The elevator cab shall be supported by the car sling The car sling shall be made of structural and formed steel and equipped with guide rollers and Type A roller safeties complete with sl...

Page 21: ...in cab 4 2 9 14 Phone in cab PART 5 EXECUTION 5 1 Examination All site dimensions and conditions shall be verified to ensure they meet specifications codes and regulations 5 2 Installation Confirm that all site dimensions and conditions match those specified on shop drawings Do not proceed with installation if the site dimensions and conditions are not acceptable Elevator shall be installed by tra...

Reviews: