Page | 20
Flame blows out on low setting
or has uneven heat distribution
•
Check for spider webs or insect nest.
•
Cold appliance needs to be preheated for 5 minutes on high
setting.
•
Cold and windy weather will require you to move appliance
away from the wind.
•
Lack of fuel. Check to see cylinder valve is open and cylinder
has fuel.
Low heat with the knob on
“HIGH”
•
Check to see if the fuel hose is bent or kinked.
•
Make sure the appliance area is clear of dust.
•
Check your gas supply and gas pressure.
•
If it is only one burner that appears low, make sure the orifice or
burner is clean.
Appliance is too hot
•
Excess grease build-up causing grease fires.
•
Damaged or faulty regulator.
Replace with factory authorized parts.
•
Cook on a lower temperature setting.
Flame behind control panel or
control knob area
IMMEDIATELY shut off cylinder valve and allow grill to cool.
•
C
heck for spider webs or insect nest.
•
Gas is leaking from a faulty connection. Tighten connections
with an adjustable wrench and replace damaged parts. Perform
a leak test on all connections before cooking on appliance
again.
Fire at any connection
IMMEDIATELY shut off cylinder valve and allow appliance to
cool.
•
Gas is leaking from a faulty connection. Tighten connections
with an adjustable wrench and replace damaged parts.
•
Perform a leak test on all connections before cooking on
appliance again.