background image

Specifications 

SuperSync15 

Input Voltage: 12Vdc
Input Current: 15A
Input Connection: 

4-pin DIN

Output Voltage: 5.2V
Output Current: 

2.1A Max per Port

Output Power: 

10W Max per Port

Output Power (Total): 

163.8W Maximum

Input/Output Connectors:  16 x USB Type-A,  
 

1 x 4-pin DIN

Ambient Operating  

0 ~ 35°C 

Temperature Range: 
Relative humidity: 

5% to 95%  

 non-condensing
Dimensions (approx.): 

198.4 long x 73 wide  

 

x 40 high mm

Approximate weight: 

1.6 kg (inc PSU)

Power Supply 

Input Voltage: 100-250Vdc
Input Current: 

2.5A @ 115 Vac

Input Frequency: 50-60Hz
Input Connector: C14
Output Voltage: 12Vdc
Output Current: 15A
Output Power: 180W 
Output Connector: 

4-pin DIN

 
 
  

 

 

Certifications 

•  Independently safety tested by the Underwriters 

Laboratory (UL) under file #E346549

•  CE Tested and marked
•  CB Certificate
•  FCC Part 15 Tested and marked
•  RoHS Compliant

•  China CCC certification
•  Japanese PSE certification (pending)
•  Complies with the latest EN60950 safety 

requirements for ITE

•  Housed within a UL94-V0 specification fire 

enclosure 

Safety Guidelines and Precautions 

Please read and understand these  
guidelines prior to installation or use. 

The SuperSync15 has ESD, over-voltage, over-
current and over-temperature protection. However, 
to use the equipment safely you should follow all 
local regulations relating to the use of electrical  
equipment and note that: 

•  Failure to install and operate the equipment  

in accordance with all local and these safety  
guidelines may result in unit failure, electrical 
shock and personal injury.

•  The plug on the power cord is considered the 

“disconnect device” and consequently the mains 
outlet should be located near the hub, easily 
accessible in case the power supply needs to be 
isolated from the mains power.

•  If there is a liquid spillage over a ventilation 

slot, external data/power connector or product 
aperture, remove power from the unit without 
contacting the liquid immediately.

 
 

www.cambrionix.com

10

Summary of Contents for SuperSync15

Page 1: ...SuperSync15 USER GUIDE Charge Connect Manage ...

Page 2: ...s 5 4 4 Endpoint limitations to scalability 6 4 4 Endpoint limit fix 6 5 Manage Ports Devices using Cambrionix Software 7 5 1 LiveViewer 7 5 2 Command Line Instructions CLI 8 5 3 Cambrionix API 9 6 Advanced Usage 9 6 1 Updating the SuperSync15 firmware 9 6 1 1 Update procedure for MacOS 9 6 1 2 Update procedure for Windows 9 6 1 3 Running Updater Instructions 9 7 Specifications 10 8 Certifications...

Page 3: ...is attached the host can control operation of the ports using freely available software Devices can be charged synchronised and monitored through Cambrionix s LiveViewer App the Application Programming Interface API or Command Line Instructions Cambrionix s free monitoring and control software can be downloaded from our website https cambrionix com The SuperSync15 is fully compliant with SuperSpee...

Page 4: ...ng USB3 0 compliant cables Once the devices are connected the algorithm will detect the highest charge rate allowable for each attached device Charging at the optimum rate up to 2 1 A specified by the manufacturer will commence once profiling is complete Depending on the state of charge of the device attached this may take tens of seconds 4 Using when connected to a host computer 4 1 Charging When...

Page 5: ...ogy or daisy chained to allow more devices to be managed from a single host computer simultaneously Each SuperSync15 needs to be connected to mains power individually and the first SuperSync15 in the chain should be connected to the local computer through the SuperSync15 s host port Five additional SuperSync15 can be attached to the downstream USB ports of the first SuperSync15 by their host ports...

Page 6: ...rmation about the device are read by the Host and a device driver is assigned and loaded Data transfer can only begin when enumeration is complete When data is about to be sent from one device to another the device address and endpoint number are sent by the Host as a token packet This token packet forms part of the data string or message and because USB3 0 devices are allocated both USB2 EHCI and...

Page 7: ...Sync Off Profile Charging profile Duration how long the device has been attached End time time the battery reaches a threshold full level Current instantaneous charge current in mA Energy present energy rate in Wh Tick boxes adjacent to each port symbol allow that port mode to be changed When the port is in Sync mode only instantaneous current can be monitored through LiveViewer When the port is i...

Page 8: ...ow voltage and temperature limits list_profiles List all profiles on system en_profile i 1 0 Enable 1 or disable 0 profile i set_profiles p l Set profiles l associated with port p get_profiles p List profiles associated with port p sec arm disarm Set or reveal security mode host auto manual Show if USB host is present and set mode change id Show id string bd Board description logc s Report mA for ...

Page 9: ... for MacOS Locate and double click the Cambrionix Updater application file which has a dmg file extension downloaded from our website then follow the instructions in 6 1 3 below 6 1 2 Update procedure forWindows Locate and double click the Cambrionix Updater application file which has a zip file extension downloaded from our website Right click the zip file and choose Open with Windows Explorer to...

Page 10: ...e PSE certification pending Complies with the latest EN60950 safety requirements for ITE Housed within a UL94 V0 specification fire enclosure 9 Safety Guidelines and Precautions Please read and understand these guidelines prior to installation or use The SuperSync15 has ESD over voltage over current and over temperature protection However to use the equipment safely you should follow all local reg...

Page 11: ...ng the power switch on the product Do not use a damaged power cord or plug or a loose power socket An electric shock or fire may result Do not power multiple products from a single power socket Overheated power sockets may cause a fire Do not touch the power plug with wet hands An electric shock may result Insert the power plug all the way into the socket so that it is not loose An unsecured conne...

Page 12: ...Cambrionix Ltd St Johns Innovation Centre Cowley Road Cambridge CB4 0WS United Kingdom T 44 0 1223 755 520 E enquiries cambrionix com W www cambrionix com SS15S_v3_0719 ...

Reviews: