background image

If in any doubt about how to correctly operate or maintain your Cambrionix system  

product or OEM module, or if any part of this safety document is unclear or confusing,  

please do not use your product and contact Cambrionix before proceeding further.

Important Electrical and Safety Messages

Safety warning

Potential consequence if ignored

Do not modify the product in any way. 

Fire, electric shock or personal injury may occur.

Do not dismantle the product. 

Fire, electric shock or personal injury may occur.

Do not bend, compress or drill into any part of the product. 

Damage, electric shock or personal injury may occur.

Parts of Cambrionix products may become hot during  
operation. Do not obstruct air vents on the product or operate the 
product in an environment where the ambient temperature is outside 
the recommended operating temperature region. 

An increased internal temperature may cause a fire.

Cambrionix products are not reverse-polarity protected.  
The power connections MUST be connected correctly.  
If in doubt, please contact Cambrionix.

Damage to your Cambrionix product may occur. A fire or electric shock 
may result.

Do not short circuit the Power Supply Unit (PSU) supplied  
with your Cambrionix product.

Sparks, fire or electric shock may result.

Ensure dust does not collect around the power plug pins  
or power socket, or in or around the air vents to the extent  
it causes a reduction in air circulation. 

A fire may result if there is combustible material within the power 
socket or around the power plug, or if the internal  
temperature increases due to lack of air circulation.

Do not allow liquids to come into contact with the unit or  
power supply.

Fire, electric shock or personal injury may occur.

Keep the mains power socket (where the power cord is  
connected) unobstructed.

The power cord must be disconnected to cut off power to the product 
when an issue occurs. Note that the product may not be completely 
powered down by only using the power switch on the product.

Do not use a damaged power cord or plug, or a loose power socket.

An electric shock or fire may result.

Do not power multiple products from a single power socket. 

Overheated power sockets may cause a fire.

Do not touch the power plug with wet hands.

An electric shock may result.

Insert the power plug all the way into the socket so that it is not loose. 

An unsecured connection may cause a fire.

Connect the power plug to an earthed socket. 

Failure to connect use an earthed socket may result in an electric 
shock or injury.

Do not bend or pull the power cord with force. Be careful not  
to leave the power cord underneath a heavy object. 

Damage to the power cord may result in fire or electric shock.

Do not place the power cord near heat sources.

A fire or electric shock may result.

Only use the power cord provided (if applicable).

A fire or electric shock may result.

Only use the power supply provided with the product  
(if applicable). 

A fire or electric shock may result.

Do not disconnect the power cord while the product is being used.

The product may become damaged by electric shock.

Cambrionix OEM modules are susceptible to Electrostatic Discharge 
(ESD). OEM modules should be handled in an ESD safe area. 

Damage to your Cambrionix OEM module may occur.

There are sharp edges, corners and components.  
Suitable protective equipment must be worn during handling  
of Cambrionix OEM modules.

Personal injury may occur.

No power supply is shipped with a Cambrionix OEM module. Please 
contact your power supply manufacturer directly for safety related 
information.

Fire, electric shock or personal injury may occur. Please see the 
installation instructions for your Cambrionix product for correct wiring 
requirements.

When mounting a Cambrionix OEM module, all mounting holes should 
be used with appropriate spacers, screws and a torque level of 1.1Nm.

Damage or personal injury may occur.

This product can expose you to chemicals, including Nickel, which is known  
to the State of California to cause cancer or birth defects or other reproductive  
harm. For more information, go to www.p65Warnings.ca.gov 

SuperSync15 

USER GUIDE

11

Summary of Contents for SuperSync15

Page 1: ...SuperSync15 USER GUIDE Charge Connect Manage ...

Page 2: ...s 5 4 4 Endpoint limitations to scalability 6 4 4 Endpoint limit fix 6 5 Manage Ports Devices using Cambrionix Software 7 5 1 LiveViewer 7 5 2 Command Line Instructions CLI 8 5 3 Cambrionix API 9 6 Advanced Usage 9 6 1 Updating the SuperSync15 firmware 9 6 1 1 Update procedure for MacOS 9 6 1 2 Update procedure for Windows 9 6 1 3 Running Updater Instructions 9 7 Specifications 10 8 Certifications...

Page 3: ...is attached the host can control operation of the ports using freely available software Devices can be charged synchronised and monitored through Cambrionix s LiveViewer App the Application Programming Interface API or Command Line Instructions Cambrionix s free monitoring and control software can be downloaded from our website https cambrionix com The SuperSync15 is fully compliant with SuperSpee...

Page 4: ...ng USB3 0 compliant cables Once the devices are connected the algorithm will detect the highest charge rate allowable for each attached device Charging at the optimum rate up to 2 1 A specified by the manufacturer will commence once profiling is complete Depending on the state of charge of the device attached this may take tens of seconds 4 Using when connected to a host computer 4 1 Charging When...

Page 5: ...ogy or daisy chained to allow more devices to be managed from a single host computer simultaneously Each SuperSync15 needs to be connected to mains power individually and the first SuperSync15 in the chain should be connected to the local computer through the SuperSync15 s host port Five additional SuperSync15 can be attached to the downstream USB ports of the first SuperSync15 by their host ports...

Page 6: ...rmation about the device are read by the Host and a device driver is assigned and loaded Data transfer can only begin when enumeration is complete When data is about to be sent from one device to another the device address and endpoint number are sent by the Host as a token packet This token packet forms part of the data string or message and because USB3 0 devices are allocated both USB2 EHCI and...

Page 7: ...Sync Off Profile Charging profile Duration how long the device has been attached End time time the battery reaches a threshold full level Current instantaneous charge current in mA Energy present energy rate in Wh Tick boxes adjacent to each port symbol allow that port mode to be changed When the port is in Sync mode only instantaneous current can be monitored through LiveViewer When the port is i...

Page 8: ...ow voltage and temperature limits list_profiles List all profiles on system en_profile i 1 0 Enable 1 or disable 0 profile i set_profiles p l Set profiles l associated with port p get_profiles p List profiles associated with port p sec arm disarm Set or reveal security mode host auto manual Show if USB host is present and set mode change id Show id string bd Board description logc s Report mA for ...

Page 9: ... for MacOS Locate and double click the Cambrionix Updater application file which has a dmg file extension downloaded from our website then follow the instructions in 6 1 3 below 6 1 2 Update procedure forWindows Locate and double click the Cambrionix Updater application file which has a zip file extension downloaded from our website Right click the zip file and choose Open with Windows Explorer to...

Page 10: ...e PSE certification pending Complies with the latest EN60950 safety requirements for ITE Housed within a UL94 V0 specification fire enclosure 9 Safety Guidelines and Precautions Please read and understand these guidelines prior to installation or use The SuperSync15 has ESD over voltage over current and over temperature protection However to use the equipment safely you should follow all local reg...

Page 11: ...ng the power switch on the product Do not use a damaged power cord or plug or a loose power socket An electric shock or fire may result Do not power multiple products from a single power socket Overheated power sockets may cause a fire Do not touch the power plug with wet hands An electric shock may result Insert the power plug all the way into the socket so that it is not loose An unsecured conne...

Page 12: ...Cambrionix Ltd St Johns Innovation Centre Cowley Road Cambridge CB4 0WS United Kingdom T 44 0 1223 755 520 E enquiries cambrionix com W www cambrionix com SS15S_v3_0719 ...

Reviews: