background image

5.3 

Cambrionix API

Cambrionix API allows you to monitor and control 
each port in more detail and to integrate these 
functions into your own workflow processes. The 
API comprises a daemon that can be downloaded 
from 

https://hub.cambrionix.com

 and installed on 

the host machine. Port information and control can 
be provided through the API using JavaScript  

 
Object Notation (JSON) Remote Procedure Calls 
(RPC) over TCP. JSON-RPC calls send a request 
to the API to “Get” port, device or PowerPad15S 
information, or “Set” port functions (such as mode).  
A library of sample Python code can be obtained 
from our website to help you integrate many 
of these functions into your process workflow 
alongside the full User Guide.

Advanced Usage 

6.1 

Updating the PowerPad15S firmware

From time to time Cambrionix updates the 
PowerPad15S firmware to ensure the device 
incorporates the latest features. In order to 
update the firmware on your PowerPad15S, please 
download the Cambrionix Updater and latest 
firmware file version appropriate for your host 
computer Operating System from  

https://hub.cambrionix.com

.  

 
Please follow these instructions to ensure your 
PowerPad15S has the latest version of the firmware 
installed.

6.1.1 

Update procedure for MacOS

Locate and double-click the Cambrionix Updater 
application file (which has a .dmg file extension) 
downloaded from our website, then follow the 
instructions in 6.1.3 below:

6.1.2 

Update procedure for Windows

Locate and double-click the Cambrionix Updater 
application file (which has a .zip file extension) 
downloaded from our website.   
Right-click the .zip file and choose ‘Open with 
‘Windows Explorer’ to show the contents of the 
compressed file. Double-click the .exe file within the 
compressed file to run the application and follow 
the below instructions:

6.1.3 

Running Updater Instructions

MacOS: 

Double-click the Cambrionix Updater file 

and drag into your applications folder.  

Windows:

 Double-click the Cambrionix Updater.

This will open the Cambrionix Updater window.

Click ‘Scan’ to list the Cambrionix products  
connected to your computer.

Click ‘File…’ to open a Finder/Explore window to 
allow you to navigate to and select the firmware 
file (which has a .enfir extension) previously 
downloaded.

The Cambrionix Updater window will now show  
one or more Cambrionix products as well as the  
firmware file selected to update the product(s).  
Please ensure each Update box is ticked for all  
products requiring updates. 

 

Press ‘Go’ once all the products to update have  
been selected.

Please Note: The ‘Reboot’ checkbox should remain  
checked. This will reboot the Cambrionix product  
once the programming is successful.

SuperSync15 

USER GUIDE

9

Summary of Contents for SuperSync15

Page 1: ...SuperSync15 USER GUIDE Charge Connect Manage ...

Page 2: ...s 5 4 4 Endpoint limitations to scalability 6 4 4 Endpoint limit fix 6 5 Manage Ports Devices using Cambrionix Software 7 5 1 LiveViewer 7 5 2 Command Line Instructions CLI 8 5 3 Cambrionix API 9 6 Advanced Usage 9 6 1 Updating the SuperSync15 firmware 9 6 1 1 Update procedure for MacOS 9 6 1 2 Update procedure for Windows 9 6 1 3 Running Updater Instructions 9 7 Specifications 10 8 Certifications...

Page 3: ...is attached the host can control operation of the ports using freely available software Devices can be charged synchronised and monitored through Cambrionix s LiveViewer App the Application Programming Interface API or Command Line Instructions Cambrionix s free monitoring and control software can be downloaded from our website https cambrionix com The SuperSync15 is fully compliant with SuperSpee...

Page 4: ...ng USB3 0 compliant cables Once the devices are connected the algorithm will detect the highest charge rate allowable for each attached device Charging at the optimum rate up to 2 1 A specified by the manufacturer will commence once profiling is complete Depending on the state of charge of the device attached this may take tens of seconds 4 Using when connected to a host computer 4 1 Charging When...

Page 5: ...ogy or daisy chained to allow more devices to be managed from a single host computer simultaneously Each SuperSync15 needs to be connected to mains power individually and the first SuperSync15 in the chain should be connected to the local computer through the SuperSync15 s host port Five additional SuperSync15 can be attached to the downstream USB ports of the first SuperSync15 by their host ports...

Page 6: ...rmation about the device are read by the Host and a device driver is assigned and loaded Data transfer can only begin when enumeration is complete When data is about to be sent from one device to another the device address and endpoint number are sent by the Host as a token packet This token packet forms part of the data string or message and because USB3 0 devices are allocated both USB2 EHCI and...

Page 7: ...Sync Off Profile Charging profile Duration how long the device has been attached End time time the battery reaches a threshold full level Current instantaneous charge current in mA Energy present energy rate in Wh Tick boxes adjacent to each port symbol allow that port mode to be changed When the port is in Sync mode only instantaneous current can be monitored through LiveViewer When the port is i...

Page 8: ...ow voltage and temperature limits list_profiles List all profiles on system en_profile i 1 0 Enable 1 or disable 0 profile i set_profiles p l Set profiles l associated with port p get_profiles p List profiles associated with port p sec arm disarm Set or reveal security mode host auto manual Show if USB host is present and set mode change id Show id string bd Board description logc s Report mA for ...

Page 9: ... for MacOS Locate and double click the Cambrionix Updater application file which has a dmg file extension downloaded from our website then follow the instructions in 6 1 3 below 6 1 2 Update procedure forWindows Locate and double click the Cambrionix Updater application file which has a zip file extension downloaded from our website Right click the zip file and choose Open with Windows Explorer to...

Page 10: ...e PSE certification pending Complies with the latest EN60950 safety requirements for ITE Housed within a UL94 V0 specification fire enclosure 9 Safety Guidelines and Precautions Please read and understand these guidelines prior to installation or use The SuperSync15 has ESD over voltage over current and over temperature protection However to use the equipment safely you should follow all local reg...

Page 11: ...ng the power switch on the product Do not use a damaged power cord or plug or a loose power socket An electric shock or fire may result Do not power multiple products from a single power socket Overheated power sockets may cause a fire Do not touch the power plug with wet hands An electric shock may result Insert the power plug all the way into the socket so that it is not loose An unsecured conne...

Page 12: ...Cambrionix Ltd St Johns Innovation Centre Cowley Road Cambridge CB4 0WS United Kingdom T 44 0 1223 755 520 E enquiries cambrionix com W www cambrionix com SS15S_v3_0719 ...

Reviews: