Way to enter menu : * (Hold down for more than 2 seconds), (Admin password) #
Menu
Parameter or operation step
Function
Default
value
57
0#
The doorbell key is invalid.
0
1#
The doorbell key is valid, but without volume.
2#
The doorbell key is valid, with “ding dong”
tone.
60
(0-255)#
Set facility code
0
61
0#
D0&D1 output wiegand format.
0
1#
D0 output RS232-TTL-HEX format.
2#
D0 output RS232-TTL-ASCII-8 format.
3#
D0 output RS232-TTL-ASCII-10 format.
62
(26-66)#
The wiegand output format for reading card
can be set from 26-66 bits.
26
63
0#
Wiegand output without parity check.
1
1#
wiegand output with parity check(EO format).
64
0#
Single key output, 4 bits wiegand data(no check bit).
0
1#
Single key output, 6 bits wiegand data( with
parity bit).
2#
Single key output, 8bits wiegand data(with
complement check bit).
3#
4 digit key buffered output
4#
1-5 digit key + # key buffered output
5#
6 digit key buffered output
5.2 Single-door mode management menu summary table
Way to enter menu : * (Hold down for more than 2 seconds), (Admin password) #
Menu
Parameter or operation step
Function
Default
value
00
(New Admin Password) #, (Repeat new Admin
Password)
Change admin password
888888
(8 digits )#
Set Super-open-password
0000#
Delete Super-open-password
01
0#, read card, read card, …
Set 1-3 Set-cards.
1#, read card, read card, …
Set 1-3 Add-cards.
2#, read card, read card, …
Set 1-3 Delete-cards.
3#, read card, read card, …
Set 1-3 Super-open-cards.
4#, read card, read card, …
Set 1-3 Anti-duress-cards.
5#, read card, read card, …
Set 1-3 Authorization-cards.
6#, read card, read card, …
Set 1-3 Normal-open-cards.
02
0000, #
Delete 21 admin cards
0#
Delete 3 Set-cards.