background image

Page 1 of 20

Door Activation Devices 

1. DESCRIPTION 

The CV-603PS-K1 is a kit that includes all the central 
components for the MProxBLE controller. The CV-603 
MProxBLE is a stand alone controller housed in a plastic 
enclosure that can be DIN mounted.To configure the controller, 
the CV-603 application is available on the Appstore for iPhone® 
users and on the Google Play for Android® users.

2. SPECIFICATIONS

Power supply

12VDC

Average consumption

< 100 mA

Receiver Frequency

433Mhz

Number of users 

2000 

Number of events 

3000 

Number of reader inputs

Types of reader input

Wiegand 26, 30, 34, 37 bit

Number of relay outputs

Types of relay outputs

Timed 1-180 seconds
Momentary, bi-stable/latch

Contact rating

30VDC @ 1 Amp

Operating Temperature

 -4°F to 131°F (-20°C to +55°C) 

DIN rail mount

Yes

IP ratings

IP 20

Weight

7 oz. (200 g)

Size of controller housing.

(For metal cabinet, refer to 

last page.)

4-1/2" H x 3-1/2" W x 1-3/4" D 

(115mm x 90mm x 44mm)

ID reading

STATE

LED 2: RED

Denied ID

2 Flashes

Authorized 

ID

On 1s

4. VISUAL INDICATOR LED ON MPROXBLE 

CONTROLLER

Smartphone 

connection

STATE

LED 1: BLUE

Waiting for 

smartphone 

connection

Power

1 Flash every 5s

Smartphone 

connected

Power

ON

3. PROGRAMMING

The MProxBLE application is available on iPhone® (Appstore) 
and Android® (Google Play).

Power

Power

CV-603 MProxBLE Controller /  
CV-603PS-K1 MProxBLE Controller Cabinet Kit

INSTALLATION INSTRUCTIONS

CV-603-BLE

CV-603PS-K1

Summary of Contents for CV-603

Page 1: ...of relay outputs 2 Types of relay outputs Timed 1 180 seconds Momentary bi stable latch Contact rating 30VDC 1 Amp Operating Temperature 4 F to 131 F 20 C to 55 C DIN rail mount Yes IP ratings IP 20...

Page 2: ...Request to Exit PIR REX Detector Door Strike 12 VDC Wire Antenna AC AC Transformer DC Output AC DC 12V 6V BATT BATT Battery Leads ve ve Connect positive wire to colored wire representing the preferre...

Page 3: ...twice the credential is being denied by the controller c If the credential is approved by the controller the door strike will energize for the pre set period duration The door strike will energize for...

Page 4: ...rmer 16VAC 40 VA Card Reader AC to DC Power Supply Wire Antenna AC AC Transformer DC Output AC DC 12V 6V BATT BATT Battery Leads Cathode mark Diode Can be replaced with a MOV D1 grey orange Door Statu...

Page 5: ...d credential in front of the card reader The card reader s red LED indicates it is powered When the credential is within 2 inches the reader will beep and the controller red LED will pulse on 1 second...

Page 6: ...er CV 603 Transformer 16VAC 40 VA Card Reader AC to DC Power Supply Door Strike 12 VDC Wire Antenna AC AC Transformer DC Output AC DC 12V 6V BATT BATT Battery Leads 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15...

Page 7: ...Cx 12 PLUS module The door operator will trigger to operate after the door strike has been energized Once the pre set periods have expired the door ope rator and strike shall de energize from the Cx 1...

Page 8: ...N INSTRUCTIONS Gate Operator Card Reader Loop Detector Loop Detector Card Reader Gate Operator Power Supply 12 VDC GATE 1 GATE 2 TWO VEHICLE GATES ANTI PASSBACK Antenna 12 V GND Data 0 Data 1 Data 1 D...

Page 9: ...ops in front of gate A sensor or loop detector will validate the position of the vehicle and enable both the card reader and receiver If the device wired to the VAL1 or VAL2 terminals do not detect th...

Page 10: ...2 Take t holes from over the sn nuts onto t place 3 Push snaptrack hook onto BLE Base and Dinrail ASSEMBLY 1 Take the bottom of the BLE base and hook it onto the bottom of the DIN rail Then take the t...

Page 11: ...Page 11 of 20 CV 603 MPROXBLE CONTROLLER CV 603PS K1 MPROXBLE CONTROLLER CABINET KIT INSTALLATION INSTRUCTIONS 41 8 105mm 2 3 4 70mm 1 4 5mm Drill 1 4 for screw 4 places 7 CV 603 BLE TEMPLATE...

Page 12: ......

Page 13: ...onals perform maintenance at the times and intervals required by the installer by the manufacturer and by current law All installation maintenance repair and cleaning operations must be documented The...

Page 14: ...d Logo used for app 2 Open the app and click on UPDATE LIST icon a A default name for your controller will appear The title will state uninitialized 3 Tap on the default name and the home page will ap...

Page 15: ...it Wiegand cards 6 Scheduling A pop up message will appear Do you want to configure a schedule now Click Yes to proceed to the Time table a You can rename the default name STANDARD to M F as an exampl...

Page 16: ...you added more schedules you can select the schedule previously defined Lock and unlock Schedule Select one of the predefined schedules Select one of the predefined schedules Select one of the predef...

Page 17: ...an alarm condition will occur Once you have made the selections click on the VALIDATE icon A pop up alert message will appear to confirm your settings have been saved Click ok to close Alarm Output R...

Page 18: ...each Wiegand card number manually or auto enroll the ID number using the ID READ icon NOTE It is recommended that you use card credentials with the same facility code number you entered on Central Set...

Page 19: ...elections turned on User management Backup and History to perform their daily tasks To manually reset alarms relay commands will need to be selected ANTI PASS BACK FEATURE MProxBLE uses hard anti pass...

Page 20: ...6 152 7mm 9 5 8 243 9mm 7 7 8 200 2mm 11 1 8 281 4mm CV 603 MPROXBLE CONTROLLER CV 603PS K1 MPROXBLE CONTROLLER CABINET KIT I NS TAL LATI ON INST RUCTI ONS...

Reviews: