background image

Inside

Wall Switch

(always unlocks

& opens door)

FILENAME:

WC-13-7 wiring diagram.vsd

DRAWING No: DRG-CX-WC-13-7

WC-13 Washroom Package 

Wiring Diagram 

(

normally unlocked) 

SCALE:  NONE

DRAWN BY: DGW

REVISED:

DATE:  07/22/14

Magnetic

Contact

Switch

12 - 24 V

AC/DC

 Power

Outside

Wall Switch

CM-45/4GRESE1

(or similar)

Inside

Push to Lock

CM-45/8GRESE1

(or similar)

Fail-Safe

Electric Strike

Shown

MOV

Wire MOV 

(supplied) 

directly to strike

(If Fail-Secure lock is 

used, wire to 

Terminals 1 & 2)

N.C.

The following items are required, but NOT included:
- Door Operator
- Electric Strike
- Inside Activate wall switch
- 12 / 24V power supply

The following are part of the WC-13 package:
- CX-33 Relay
- CX-MDC Door Contacts
- CM-45/4GRESE1 Illuminated Push plate switch

PUSH TO OPEN, with signage

- CM45/8GRESE1 Illuminated Push plate switch 

PUSH TO LOCK, with signage

Contacts closed

when Door

is closed 

12 / 24 VDC

 Power

For Strike

For Normally Locked Door, see over...

PUSH

TO

LOCK

12

/24

Po

w

er

Remot

e

N

.O

Rela

Output

LED 1

CX-33

LED 2

LED 3

DISPLAY

Relay 1

Relay 2

Relay 3

N

/C

N

/O

C

O

M

N

/C

N

/O

C

O

M

N

/C

N

/O

C

O

M

PO

W

ER

12

/2

4V

AC

/D

C

D

R

1

D

R

2

D

R

3

D

R

4

W

ET

IN

PU

T

IN

PU

T

IN

PU

T

IN

PU

T

- I

N

PU

T

MENU

UP

DOWN

0.0.

7

Door

Operator

PUSH

TO

OPEN

PUSH

TO OPEN

12

/24

Po

w

er

Remot

e

N

.O

Rela

Output

Important: 
Ensure wiring polarity is 
consistent from Relay 3 to each 
Aura

´

s Remote Input terminals.

NOTE: This Drawing should be 

used in addition to each products 

respective Installation Manual. 

(not in place of)

+

-

Part # 40-82D003

Red IDL

G/B

Red ACT

G/B

4

3

LOC/REM

RELAY 2

1

Enable

SPEAKER

ON

1

2

3

4

Color Select

Aura 

Dip Switch 

Settings

ON

CAMDEN DOOR CONTROLS

5502 Timberlea Blvd.

Mississauga, Ontario

L4W 2T7