Inside
Wall Switch
(always unlocks
& opens door)
FILENAME:
WC-13-7 wiring diagram.vsd
DRAWING No: DRG-CX-WC-13-7
WC-13 Washroom Package
Wiring Diagram
(
normally unlocked)
SCALE: NONE
DRAWN BY: DGW
REVISED:
DATE: 07/22/14
Magnetic
Contact
Switch
12 - 24 V
AC/DC
Power
Outside
Wall Switch
CM-45/4GRESE1
(or similar)
Inside
Push to Lock
CM-45/8GRESE1
(or similar)
Fail-Safe
Electric Strike
Shown
MOV
Wire MOV
(supplied)
directly to strike
(If Fail-Secure lock is
used, wire to
Terminals 1 & 2)
N.C.
The following items are required, but NOT included:
- Door Operator
- Electric Strike
- Inside Activate wall switch
- 12 / 24V power supply
The following are part of the WC-13 package:
- CX-33 Relay
- CX-MDC Door Contacts
- CM-45/4GRESE1 Illuminated Push plate switch
PUSH TO OPEN, with signage
- CM45/8GRESE1 Illuminated Push plate switch
PUSH TO LOCK, with signage
Contacts closed
when Door
is closed
12 / 24 VDC
Power
For Strike
For Normally Locked Door, see over...
PUSH
TO
LOCK
12
/24
V
Po
w
er
Remot
e
N
.O
.
Rela
y
Output
LED 1
CX-33
LED 2
LED 3
DISPLAY
Relay 1
Relay 2
Relay 3
N
/C
N
/O
C
O
M
N
/C
N
/O
C
O
M
N
/C
N
/O
C
O
M
PO
W
ER
12
/2
4V
AC
/D
C
D
R
Y
1
D
R
Y
2
D
R
Y
3
D
R
Y
4
+
W
ET
IN
PU
T
IN
PU
T
IN
PU
T
IN
PU
T
- I
N
PU
T
MENU
UP
DOWN
0.0.
7
Door
Operator
PUSH
TO
OPEN
PUSH
TO OPEN
12
/24
V
Po
w
er
Remot
e
N
.O
.
Rela
y
Output
Important:
Ensure wiring polarity is
consistent from Relay 3 to each
Aura
´
s Remote Input terminals.
NOTE: This Drawing should be
used in addition to each products
respective Installation Manual.
(not in place of)
+
-
Part # 40-82D003
Red IDL
G/B
Red ACT
G/B
4
3
LOC/REM
RELAY 2
1
Enable
SPEAKER
ON
1
2
3
4
Color Select
Aura
Dip Switch
Settings
ON
CAMDEN DOOR CONTROLS
5502 Timberlea Blvd.
Mississauga, Ontario
L4W 2T7