background image

Door Status Sensor  

(Closed position)

 

White = N/O
Orange = COM
Grey = N/C

Push Buttons

Keypads

Strikes

Magnetic Locks

Key Switches

Relays & Timers

Access Control

5502 Timberlea Blvd., 

Mississauga, ON Canada 

L4W 2T7

www.camdencontrols.com 

Toll Free: 1.877.226.3369

File: CX-ED1259LDesigner 

        Installation Instructions.indd R3 

Revision: 22/02/2018  

Part No.: 40-82B205

CX-ED1259-L ‘RIM’ Electric Strike

Page 3 of 3

Orange

White

Grey

Black

Red

Blue

Green

Red

Green

Black
Blue

12V

24V

Black

Red

Blue

Green

(+12V)

(-)

Varistor

(+24V)

(-)

Varistor

5. Connections

6. Wiring

7. Setting Fail-Secure/Fail Safe

A varistor is provided to protect/prevent strike from spikes.  

Connect varistor between input wires.

Note: The door strikes are to be powered via a class 2 power 

limit output from a control panel or power supply that is UL 

listed to UL Burglar Alarm/Access control standards.

How to modify fail-safe to fail-secure or vice versa.
1.  Loosen the screw at the back of the Electric strike as per   

the diagram below.

A varistor is provided to protect strike from spikes. 

Connect varistor to between input wires.

POWER  

12V AC/DC

 

Red/Black:   +12V 

Blue/Green:   Ground

24V AC/DC

 

Red:  

+24V 

Black/Blue:       - 

Green:  

Ground

Fail safe 

 Fail secure

3. 

Rotate 180°to 

change the mode 

of operation

2. 

Slide 

mechanism 

out

1. 

Remove cover 

plate