background image

CX-ED1410 ‘Universal’ Fire Electric Strike

1. Prepare the door jamb as per the appropriate drawing.
2. Install mounting brackets to jamb using M5x12 screws  

  and pressed metal nuts. Do not tighten.
3. Spacers are used to assure flush final assembly of  

  faceplate into jamb. Add one or more spacers between  

  jamb and mounting bracket when face plate extends  

  beyond the jamb. When the faceplate sits inside the  

  jamb, spacers must be added between the mounting  

  bracket & the lip bracket. Make sure the clearance hole in  

  the spacer aligns with the hole in mounting bracket.
4. Connect wires coming from the low voltage side of the  

   transformer to wires (black) from strike.
5. Install electric strike jamb by attaching with # 10-32  

   screws and lockwashers.
6.  Securely tighten the M5x12 screws holding the mounting 

brackets to jamb.

4. Installation

Mounting Bracket (2pcs)

Drill & Countersink For
M5 Flat-Head Screw (2pcs)
Pressed Metal Nut

M5x12

Flat-Head

Screw (4pcs)

Horizontal

Centerline

M5x12

Flat-Head

Screw (2pcs)

Jamb

Vertical Centerline

Vertical Centerline

Centerline

Jamb

126

105

37

48

35

86

126

155

86

35

37

48

Page 2 of 3

Note: The products are intended to be installed in 

accordance with the installation wiring diagram, mechanical 

assembly drawings provided with each product, the local 

authority having jurisdiction (AHJ) and the National Electric 

Code, NFPA 70. When installed in fail secure mode, the 

local authority shall be consulted with regard to the use of 

possible panic hardware to allow emergency exit from the 

secure area.
The electric door strike shall be installed in such a way  

and in such location so as to not impair the operation of  

an emergency exit device or panic hardware mounted on  

the door.