6)

 

Check   the   gap   between   the   door   and   the   frame   (with   the   door   in   the   closed   position)   to   ensure   it   is   equal   from   
top   to   bottom,   if   it   is   not   equal,   make   the   necessary   adjustments   to   correct   this   issue.   If   the   gap   is   equal,   and   is   
greater   than   1/8”   please   ensure   you   “notch”   the   frame   as   shown   below.   

   

   

   

   

   

   

   

   

   

   

   

   

7)

 

ALWAYS   remember   to   check,   that   the   voltage   selector   is   set   to   the   correct   voltage   you   are   providing,   and   
ALWAYS   check   the   voltage   from   your   power   supply   (while   under   load),   with   a   multi-­‐meter   to   make   sure   it   is   
supplying   the   correct   voltage.   

   

   

   

   

   

   

5502 Timberlea Blvd.,  
Mississauga, ON Canada L4W 2T7 

www.camdencontrols.com  
Toll Free: 1.877.226.3369 

File: CX-EPD 2850L _NF_MAN_Rev2.doc 
Revised: Wednesday, July 17, 2013 
Part No.: 40-82B142 

Summary of Contents for CX-EPD 2850L

Page 1: ...e use Phillips screwdriver to select setting Note Pre load feature only functional with fail secure operation Latch monitoring standard on all pre load models Adjustment To change position of keeper use Phillips screwdriver to loosen 3 screws move keeper to desired location and then tighten Jamb Preparation Dimensions ...

Page 2: ...l with the edge of the frame If this is not the case use the provided support kit to compensate as shown below Connection Latch Monitoring Output Built in latch monitoring feature wired to access control system Power Input 12 24V AC DC Using a multimeter confirm that you have the correct output voltage at the power supply Using a multimeter confirm that you have the correct input voltage at the st...

Page 3: ... rubbing or binding on the top or bottom portion of the ramp 4 Check the spring latch of the lock make sure it is operating in a smooth manner Check the dead latch pin to make sure it retracts and springs back out in a smooth manner as well 5 If you find the spring latch binding or sticking at the bottom of the ramp you may have to file or grind the 90 degree edge of the spring latch slightly to a...

Page 4: ... equal and is greater than 1 8 please ensure you notch the frame as shown below 7 ALWAYS remember to check that the voltage selector is set to the correct voltage you are providing and ALWAYS check the voltage from your power supply while under load with a multi meter to make sure it is supplying the correct voltage 5502 Timberlea Blvd Mississauga ON Canada L4W 2T7 www camdencontrols com Toll Free...

Reviews: