Page 3 of 13
WC16PS SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
Display (M)
Description ( Mode you are in)
Parameters (1-15 )
H, then 1
Relay 1 Hold Time
0.0 to 50 seconds
d, then 1
Relay 2 Delay Time
0.0 to 15 seconds
H, then 2
Relay 2 Hold Time
0.0 to 50 seconds
d, then 2
Relay 3 Delay Time
Depends on Mode
H, then 3
Relay 3 Hold Time
0.0 to 50 seconds
d
Sets the display ON or OFF during operating mode
ON or OFF
A
Input delay on Activate. If other than 0.0 is selected, the input must
be held in for the time period chosen before the CX-33 will activate.
0.0 to 10 seconds
1
Set Dry Input 1 to activate on normally open or normally closed contact.
N/O OR N/C
2
Set Dry Input 2 to activate on normally open or normally closed contact.
N/O OR N/C
3
Set Dry Input 3 to activate on normally open or normally closed contact.
N/O OR N/C
4
Set Dry Input 4 to activate on normally open or normally closed contact.
N/O OR N/C
5
Set Wet Input 5 to activate on normally open or normally closed contact.
N/O OR N/C
Mounting
The Sure-Wave™ may be mounted in single or double gang electrical boxes, and 4 x 4 boxes.
NOTE: The sealing gasket (included) is recommended for outdoor or wet locations.
If using with Automatic doors install in accordance with ANSI A156.10 / A156.19.
Select from one of the following mounting subsections :