WC16PS SERIES RESTROOM CONTROL

INSTALLATION INSTRUCTIONS

CX-ED2079 'UNIVERSAL' ELECTRIC STRIKE INSTALLATION 

CX-ED2079 ‘Universal’ Electric Strike

1. Prepare the door jamb as per the appropriate drawing.
2. Install mounting brackets to jamb using M5x12 screws

and pressed metal nuts. Do not tighten.

3. Spacers are used to assure flush final assembly of

faceplate into jamb. Add one of more spacers between

jamb and mounting bracket when face plate extends

beyond the jamb. When the faceplate sits inside the

jamb, spacers must be added between the mounting

bracket & the lip bracket. Make sure clearance hole in 

spacer aligns with hole in mounting bracket.

4. Connect wires coming from the low voltage side of the

transformer to wires (black) from strike.

5. Install electric strike jamb by attaching with # 10-32

screws and lockwashers.

6. Secure M5x12 screws holding mounting brackets to jamb.

4. Installation

Mounting Bracket

Spacer

Spacer (Option)

Spacer 

M5x12 Flat-Head Screw (2pcs)

Jamp

M5x12 Screw

Vertical Centerline

Note: The products are intended to be installed in accordance 

with the installation wiring diagram, mechanical assembly 

drawings provided with each product, the local authority having 

jurisdiction (AHJ) and the National Electric Code, NFPA 70. 

When installed in fail secure mode, the local authority shall be 

consulted with regard to the use of possible panic hardware to 

allow emergency exit from the secure area.
The electric door strike shall be installed in such a way and 

in such a location so as to not impair the operation of an 

emergency exit device or panic hardware mounted on the door.

(86mm)

3-3/8”

(187mm)

7-3/8”

(36mm)

1-3/8”

(200mm)

7-7/8”

(86mm)

3-3/8”

(86mm)

3-3/8”

(168mm)

6-3/8”

(31mm)

1-7/32”

(31mm)

1-7/32”

(31mm)

1-7/32”

(105mm)

ESP1B + ESP2B

ESP3B

ESP4B

4-1/8”

(124mm)

4-7/8”

(89mm)

3-1/2”

(155mm)

6-1/8”

(173mm)

6-7/8”

(144mm)

5-11/16”

Summary of Contents for CX-WC16PS Series

Page 1: ...asily seen by patrons at a distance 2 INSTALLATION Operation at a Glance When the outside WAVE TO OPEN touchless switch is activated it will trigger its N O relay contact to send a momentary closure t...

Page 2: ...ustments The supplied CX TRX 5024 transformer will have its secondary terminals wired to the terminals on the top of the left terminal strip marked as AC Next wire the primary terminals to the AC feed...

Page 3: ...0 0 to 10 seconds 1 Set Dry Input 1 to activate on normally open or normally closed contact N O OR N C 2 Set Dry Input 2 to activate on normally open or normally closed contact N O OR N C 3 Set Dry I...

Page 4: ...Make the electrical connections to the device according to the wiring section 4 Using the dip switch located on the end of the unit set the operating mode 5 Attach the unit to the enclosure using the...

Page 5: ...ox ensure the box is plumb and square and flush with the wall surface then attach the metal adaptor plate included in the packages to the box using appropriate fasteners 2 Bring your 4 or 6 conductor...

Page 6: ...et Surface Mount Enclosure 6 32 x 3 4 2 Pcs 6 32 x 1 2 2 Pcs Polypropylene Lens Holder Set CM 331 43S Sealing Gasket IR Lens CM 331 43S Faceplate CM 331 42SW SGLR CM 325 42SW Faceplate Flush Smooth Wa...

Page 7: ...screws and lockwashers 6 Secure M5x12 screws holding mounting brackets to jamb 4 Installation Mounting Bracket Spacer Spacer Option Spacer M5x12 Flat Head Screw 2pcs Jamp M5x12 Screw Vertical Centerli...

Page 8: ...een input wires Fail Safe Changing Fail Secure 24VDC Red 24V Black Blue Green Ground How to modify fail safe to fail secure or vice versa 1 Loosen the screw as per the product diagram below 2 Rotate t...

Page 9: ...60 81C010FE Decal Print English French Sign WAIT FOR DOOR TO CLOSE 8 60 81C011 Decal Print English Sign OCCUPIED WHEN RED VACANT WHEN GREEN Single Gang SureWave Enclosure 9 CM 34BL Single Gang Black A...

Page 10: ...C16PS SERIES RESTROOM CONTROL INSTALLATION INSTRUCTIONS Page 10 of 13 File WC16PS Restroom Controls Manual indd Rev September 13 2023 Part No 40 82B239 Questions Call us toll free at 1 877 226 3369 or...

Page 11: ...DEN DOOR CONTROLS ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CAMDEN DOOR CONTROLS IS PROHIBITED Place Sign On The Door Inside The Restroom At Eye Level INSIDE THE RESTROO...

Page 12: ...ll System is installed Door Operator 120 VAC N C AC AC Outside Push To Open Inside Push To Open Push To Lock DPS NC DPS COMM WET INPUT Strike Strike Door Operator LED Control VDC VDC 1 2 3 4 CM AF540S...

Page 13: ...Page 13 of 13 WC16PS SERIES RESTROOM CONTROL INS TA LLATIO N INS TR UCTIO NS CABINET BASE L C L C 7 7 8 200 2 mm Cabinet Base Mounting Template 6 152 7 mm 6 152 7 mm 9 5 8 243 9 mm 11 1 16 281 4 mm...

Reviews: