WC17PS Series Restroom Control
INSTALLATION INSTRUCTIONS
Electrified Locks, Relays and Timers
1. GENERAL DESCRIPTION
The CX-WC17PS Restroom Control Kit allows access in and out of
a restroom with the ability to secure the door once inside. The Kit
also provides annunciation by including an Occupied light. The
designation of “PS” in the part number reflects that this kit now
comes pre-wired in a metal enclosure with a power supply which
is ready to accept all field wiring.
The CX-WC17PS Restroom Control Kit is controlled by Camden’s
advanced relay logic controller CX-33. The CX-WC17PS has two
modes. One is Mode 7 for a normally unlocked restroom and
the other is Mode 8 for a normally locked restroom. In Mode 7
when the exterior PUSH to OPEN column switch is pressed it will
trigger the door operator to open the door. In Mode 8 when the
exterior PUSH to OPEN column switch is pressed it will unlock the
strike and trigger the door operator to open the door. Once in
the restroom and the PUSH to LOCK column switch is pressed, it
will keep the door locked in either mode, and disable the exterior
PUSH to OPEN column switch, as well as, providing annunciation
with an Occupied light. When exiting the restroom, you can
either press the inside PUSH to OPEN column switch to unlock
the door and open the door or you can push the crash bar,
paddle or turn the knobset to break the door contact circuit,
which will also unlock the door and reset the system. The
Occupied light will turn off, signaling the restroom is available.
2. INSTALLATION
Operation at a Glance
When the exterior PUSH TO OPEN column switch is pressed it
will send a momentary closure to the outside PUSH TO OPEN
terminal on the CX-WC17PS allowing the door to swing open.
When the interior PUSH TO LOCK column switch is pressed it
will send a momentary closure to the to inside PUSH TO LOCK
terminal on the CX-WC17PS causing it to lock the restroom and
turn on the Occupied light. When the inside PUSH TO OPEN
column switch is pressed it will send a momentary closure to
the inside PUSH TO OPEN terminal on the CX-WC17PS causing it
to unlock the door and open it. The Occupied light will now turn
off signalling the restroom is now vacant. The restroom can also
be unlocked by opening the door from the inside which will break
the door contact circuit causing the CX-WC17PS to reset and
unlock the door.
Mounting
IMPORTANT: Do not apply power to the unit until you have fully
read the instructions and have made the required adjustments.
The CX-WC17PS cabinet should be mounted in a clean dry
location out of direct contact with the elements.
Wiring the CX-WC17PS Series Restroom
Control Kit is as follows:
The CX-WC17PS comes from Camden with the CX-33 pre-wired
to a labeled set of two terminal strips. This will make the wiring
of the push buttons easier since the wiring manual will no
longer need to be directly referenced for termination points. A
complete wiring diagram is adhered to the inside of the door
to provide a layout of the wiring as a reference when wiring the
field devices to the kit.
There are two terminal strips that mirror the locations on the
CX-33. The left strip is used for power to the CX-33, the PUSH
TO OPEN and PUSH TO LOCK column switch, the door position
switch, and the Wet trigger. The right strip is for the outputs to
drive the strike (Relay 1), door operator (Relay 2), Occupied light
(Relay3), and to provide VDC power for the door strike.
Once all field devices are wired to the CX-WC17PS then AC
power can be wired in.
IMPORTANT: Confirm the electrical panels breaker you are
going to be using is currently off. Do not wire the primary
terminals of the transformer until the secondary terminals
are connected first.
The supplied CX-TRX-5024 transformer will have its secondary
terminals wired to the terminals on the top of the left terminal
strip marked as “AC”. Next, wire the primary terminals to the AC
feed to be used. Confirm your connections and apply power by
turning on the electrical panels breaker.
Selecting a Mode
The CX-WC17PS has two restroom applications built in (Mode
7 & 8).
The default mode for the CX-WC17PS is Mode 7
(normally unlocked).
Determining which mode is correct for you will be based on
whether the restroom will be normally unlocked (Mode 7) or
normally locked (Mode 8).
There are three LED displays that will allow you to see what mode
you have selected when advancing through the modes. To change
the mode of the CX-WC17PS simply press the MENU button once
and use the UP button to advance to the desired mode.
Editing the Settings for a Mode
Camden builds in typical times for lock release and door
operator activation and is ready to use without changing any
parameters. If you need to change the timing or delay for an
output, it can be done by pressing the “MENU” button within
the mode you selected. Once the option is selected you can
use the “UP or DOWN” buttons to select the timing needed.
The first option (H & 1 flashing) will be how long relay 1 will be
activated for (0-50 seconds). The second option (d & 1 flashing)
will be how long to wait before activating relay 2 (0-15 seconds).
The third option (H & 2 flashing) will be how long relay 2 will be
activated for (0-50 seconds). The fourth option (d & 2 flashing)
will be how long to wait before activating relay 3 (0-15 seconds).
The fifth option (H & 3 flashing) will be how long relay 3 will be
activated for (0-50 seconds). See chart below.
Factory Reset (Defaulting the CX-33)
To return the CX-33 back to its factory default settings you will
need to remove power, then hold down the “MENU” button
while powering up the CX-33. Once started you will see the
firmware version listed then a number “1” will be displayed.
Reconnect your power and press the “MENU” button once then
use the “UP” or “DOWN” button to advance to the desired mode.
Fully test the operation of the CX-WC11PS for proper functionality.
Display (M)
Description (Mode you are in)
Parameters (1-15 )
H, then 1
Relay 1 Hold Time
0.0 to 50 seconds
d, then 1
Relay 2 Delay Time
0.0 to 15 seconds
H, then 1
Relay 2 Hold Time
0.0 to 50 seconds
d, then 1
Relay 3 Delay Time
Depends on Mode
H, then 1
Relay 3 Hold Time
0.0 to 50 seconds
d
Sets the display ON or OFF during operating mode
ON or OFF
A
Input delay on Activate. If other than 0.0 is selected, the input must
be held in for the time period chosen before the CX-33 will activate.
0.0 to 10 seconds
1
Set Dry Input 1 to activate on normally open or normally closed contact.
N/O OR N/C
2
Set Dry Input 2 to activate on normally open or normally closed contact.
N/O OR N/C
3
Set Dry Input 3 to activate on normally open or normally closed contact.
N/O OR N/C
4
Set Dry Input 4 to activate on normally open or normally closed contact.
N/O OR N/C
5
Set Dry Input 5 to activate on normally open or normally closed contact.
N/O OR N/C
3. CM-AF503 MOUNT INSTALLATION
Flush Mount Installation
With the back box already roughed-in, position the CM-AF503 so that the holes on the faceplate line-up with the screw holes on
the back box and tighten with supplied #6-32 screws securely in place and completely tighten the #6-32 screws in place.
Wall
CM-AF503
515
16 ''
[150mm]
3 1
16''
[77mm]
13
16 ''
[21mm]
314''
[83mm]
3 12''
[89mm]