Page 8 of 9
WC17PS SERIES RESTROOM CONTROL
INSTALLATION INSTRUCTIONS
SYSTEM OPERATION
OUTSIDE
INSIDE
120V AC/15A
DEDICATED
CIRCUIT
7
PUSH
TO OPEN
PUSH
TO OPEN
WIRE SPECIFICATION
A
2 x 18 AWG
B
2 x 22 AWG
C
6 x 22 AWG
B
A
B
B
1
4
2
4
2
CX-WC17-PS EQUIPMENT PACKAGE:
1
CX-33PS (60-40E036) - POWER SUPPLY CABINET
WITH A CX-TRX-4024 - 40VA, 24 VAC TRANSFORMER
2
CM-7536/4 - 36'' COLUMN "PUSH TO OPEN" SWITCH
3 CM-7536/8B - 36'' COLUMN ''PUSH TO LOCK'' SWITCH
4 CM-AF503 - LED ANNUNCIATOR WITH OCCUPIED AND
''LOCKED'' LABELS.
5
CX-MDA - MAGNETIC DOOR CONTACT
6
CX-ED2079 - GRADE2 UNIVERSAL ELECTRIC STRIKE
ADDITIONAL PARTS REQUIRED
BUT NOT INCLUDED WITH THE CX-WC17-PS:
7
DOOR OPERATOR - SUPPLIED BY OTHERS
3
B
A
B
A
6
5
OCCUPIED
WHEN
LIT
LOCKED
WHEN
LIT
A
CX-WC17-PS OPERATION:
A. THE DOOR IS NORMALLY CLOSED AND UNLOCKED.
B. PRESSING THE EXTERIOR COLUMN 'PUSH TO OPEN'
SWITCH OPENS THE DOOR.
C. ONCE INSIDE AND THE DOOR IS CLOSED, PRESSING THE '
PUSH TO LOCK' COLUMN SWITCH LOCKS THE DOOR,
DISABLING THE EXTERIOR ' PUSH TO OPEN' COLUMN AND
ILLUMINATES THE EXTERIOR ANNUNCIATOR TO SHOW '
OCCUPIED WHEN LIT' AND INTERIOR ANNUNCIATOR TO
SHOW 'LOCKED WHEN LIT'
D. PRESSING THE INTERIOR 'PUSH TO OPEN' SWITCH
UNLOCKS THE DOOR, DEACTIVATES THE ILLUMINATED
ANNUNCIATOR AND RESETS THE SYSTEM
E. IF THE DOOR IS OPENED MANUALLY TO EXIT THE
RESTROOM, THE OVERHEAD MAGNETIC CONTACT SWITCH
RESETS THE SYSTEM.