CX-WC17VR-PS Wiring Diagram
FILENAME:
DRAWING No:
SCALE: NONE
DRAWN BY:
REV:
DATE:
CAMDEN DOOR CONTROLS
5502 Timberlea Blvd
Mississauga, Ontario
L4W 2T7
JML
Aug 24, 2022
1
CX-WC17VR-PS Wiring Diagram
Notes
1. CX-33 can be set to Mode 7 (Normally Unlocked)
or Mode 8 (Normally Locked).
2. Mode 7 = Set Strike to Fail Safe.
3. Mode 8 = Set Strike to Fail Secure.
Door Position Switch
Transformer
CX-TRX-5024
24 VAC, 50 VA
CM-7536VR/4
Outside
Push to Open
CM-7536VR/4
Inside
Push to Open
CM-7536VR/8B
Push to Lock
Electric Strike
CX-ED2079
Wire MOV
directly to
strike or
magnet
120 VAC
N.C.
Model: 60-40E033
AC
AC
Outside
Push To Open
Inside
Push To Open
Push To
Lock
DPS NC
DPS COMM
+
WET
-
INPUT
+ Lock
+ Strike
-
Strike
*
Door
Operator
*
Green LED
Red LED
+ VDC
- VDC
PUSH
TO OPEN
MOV
Door Operator
PUSH
TO OPEN
PUSH
TO
LOCK
*
12 to 24 V DC (+)
0 V DC (Ground) (-)
Green LED
Red LED
Relay - Normally Open
Relay - Common
Relay - Normally Closed
CM221
Mode Pins:
OPEN (Default position)
= Internal mode;
LED colors will be controlled by the IR Sensor
SHORTED
= Extermal mode; LED colors will be
controlled by Yellow and White wires.
Distance Adjustment
(2” to 8”, 5 to 20 cm)
Turn clockwise
to increase range
Time Adjustment
(0.5 to 20 seconds)
For ToggleTurn
clockwise to increase
time delay
A
B
C
Page 7 of 9
CX-WC17VR-PS SERIES RESTROOM KIT
INSTALLATION INSTRUCTIONS