CV-500PPK-V.2
Installation Instructions
www.camdencontrols.com
Toll Free: 1.877.226.3369
File: CV-500PPK-V.2_NF-Man_Rev1.doc
Revised: March 8, 2011
Part No.: 40-82B131
5502 Timberlea Blvd.,
Mississauga, ON Canada L4W 2T7
*
2
Key in new 6 digit master code or
present master card
1 Beep
Green
LED
flashing
#
1 Beep Green
and RED LED
Cancel Card and PIN Code With User Number
1. Press
*.
2. Enter the 6 digit master code (for the first use, the master code default is 000000).
3. Press * or present the Master Card.6 audible beeps are emitted and the LED flashes green and red to confirm
entry into programming mode.
4. Press 3, then * to enter in the cancel card and pin code menu. 1 audible beep is emitted and the LED flashes
green.
5. To delete a card and Pin code, enter the 3 digit user number.
6. Press the * key twice (**). 1 audible beep is emitted and the LED flashes green and red.
7. Press # to exit from the programming mode. 6 beeps confirm the reader is in standby mode.
*
3
Enter User Number (000-499)
1 Beep
Green
LED
flashing
#
1 Beep Green
and RED LED
flashing
* *
1 Beep
Red
LED
Program Door Release Time
1. Press
*.
2. Enter the 6 digit master code (for the first use, the master code default is 000000).
3. Press * or present the Master Card.6 audible beeps are emitted and the LED flashes green and red to confirm
entry into programming mode.
4. Press 4, then * to enter into the door release time menu. 1 audible beep is emitted and the LED flashes green.
5. Enter the 2 digit door release time from 01 to 99 seconds. Enter 01 for second up to 99 for 99 seconds.
6. 00 sets a latched output (toggle on/off) then press the * to confirm. 1 audible beep is emitted and the LED flashes
green and red.
7. Press # to exit from the programming mode. 6 beeps confirm the reader is in standby mode.
*
4
Enter time output 2 digit
00-99 seconds
1 Beep
Green
LED
flashing
*
#
1 Beep Green
and RED LED
flashing