CV-920 Series
Page 4 of 5
Validation OK?
No
Yes
Enter “Master Code”
B + 000000
Error Beep
(3 short beeps)
1 small beep + 1 long beep + Orange LED is ‘ON’
Press
“A”
to validate and exit the menu
(orange LED OFF)
Change
Master Code
1
Enter New
Master Code
Press 6 Digits
2
Select Type of Wiegand
1
Wiegand
26bit
2
3
4
Wiegand
30bit
Wiegand
34bit
Wiegand
40bit
3
Select Output Protocol
1
2
3
Single
Wiegand
Double
Wiegand
Clock &
Data
PIN Code Length
4
0
1 - 8
for any length
with “A”
in the end
for lengths
between
1 to 8 digits
6
Presets
1
2
3
4
Wiegand
26bit
normal
Wiegand
34bit
normal
Wiegand
34bit
CV-350
Wiegand
26bit
CV-350
7
Site Code Length
1
2
3
4
No Site
Code
Site Code
between
0 to 15
Site Code
between
0 to 255
Site Code
between
0 to 65535
Enter Site
Code
8
5 digits
Backlight
9
0
1
Backlight
OFF
Backlight
ON
Direct Menu exit
Programming Flowchart
Entering Menu is always done with B + 000000 if the
Master Code is not changed.
Submenu 1 - Change Master Code.
The Master Code
must be 6 digits. After enrolling new Master Code the
CV-920 automatically exits the Menu and the new master
code must be typed to enter the menu.
Submenu 2 - Select Type of Wiegand.
With this the
Keypad can be adjusted to send 4 different Wiegand
Outputs. The Wiegand selected must be the same as the
controller’s Wiegand Input that the CV-920 Keypad is
being connected to. Example: If you use a controller that
recognizes Wiegand 34bit, then enter the menu of CV-920,
press 2, then press 3.
Submenu 3 - Select Output Protocol.
The Keypad can
send the Code by different Protocols. Use “Single Wiegand”
when connected to third party controllers. When “Single
Wiegand” is selected, what is typed on the Keypad is
sent as a Wiegand Number. Use Double Wiegand when
connected to CV-350, use Clock&Data when connected to
controller with Clock & Data input.
Submenu 4 - PIN Code Length.
If “0” is selected, then
any PIN Code with any length can be sent, but the PIN Code
must be followed with “A” for confirmation ( ex. 123 + A).
If 1 to 8 is selected the PIN Code length is determinated by
the number selected.
Submenu 6 - Presets.
The Presets are a set of
preprogrammed parameters for easy programming.
6-1
“Wiegand 26bit Normal” -
Type:
Wiegand 26bit;
Output:
Single Wiegand;
PIN Length:
4 digits;
Entry Mode:
Card or PIN Code
6-2
“Wiegand 34bit Normal” -
Type:
Wiegand 34bit;
Output:
Single Wiegand;
PIN Length:
4 digits;
Entry Mode:
Card or PIN Code
6-3
“Wiegand 34bit CV-350 Mode” -
Type:
Wiegand
34bit;
Output:
Double Wiegand;
PIN Length:
4
digits;
Entry Mode:
Card or PIN Code
6-4
“Wiegand 26bit CV-350 Mode” -
Type:
Wiegand
26bit;
Output:
Double Wiegand;
PIN Length:
4
digits;
Entry Mode:
Card or PIN Code
Presets 6-3 and 6-4 to be used always when CV-920
is connected to CV-350 firmware ver.2.42 or higher.
Submenu 7 - Site Code Length.
Set the code length sent
to Host. Defaul is “0”. To be used only in specific cases.
Submenu 8 - Enter Site Code.
Put the site code always in
5 digit format (ex. 00170).
Submenu 9 - Backlight.
Turns ON/OFF the backlight.