BY CAMDEN
CM-333 Battery Operated
with Relay Output Active Infra-red
“Hands-Free” Switches
Installation Instructions
Section 1: General Description
Sure-Wave™ Hands-Free Switch are active infra-red devices
utilizing micro burst sensor technology, designed for use
in ADA compliant automatic door control applications. The
switches eliminate the spread of germs by avoiding physical
contact and offer building occupants greater convenience
when moving through the premises. Sure-Wave™ switches
are available with either stainless steel or impact resistant
polycarbonate faceplates, in narrow (jamb), single gang or
double gang configurations. All models are ROHS compliant
with lead-free construction.
Application
Sure-Wave™ battery powered hands-free switches are
American Disability Act (ADA) compliant, and provide
barrier free access and egress to buildings and washroom
facilities. The rugged construction makes them ideal for
use on low-energy automatic doors, drive-up windows,
and interior and exterior doors in virtually any commercial
(office, retail), institutional (school, hospital or clinic), or
industrial (manufacturing) facility.
Three standard face plate widths are available:
CM-333:
2 ¾” x 4 ½” polycarbonate or stainless steel, fits
on single gang electrical boxes.
CM-333/N:
1 ¾” x 4 ½” polycarbonate or stainless steel, fits
1 ¾” door frames or our CM-23D Jamb box.
CM-333/W:
4 ½” x 4 ½” polycarbonate or stainless steel,
fits on single gang, double gang or 4 x 4 electrical boxes.
All faceplates may be ordered up with a plain face, with the
waving hand symbol (/40), with the waving hand symbol
and words: WAVE TO OPEN (/41) or with the waving hand
icon, wheelchair and words: WAVE TO OPEN (/42).
Section 2: Installation
Mounting
Sure-Wave™ may be mounted in door jambs, single or
double gang electrical boxes, and 4 x 4 boxes.
NOTE: The sealing gasket (included) is recommended for
outdoor or wet locations. If using with Automatic doors install in
accordance with ANSI A156.10 / A156.19. Select from one of
the following three mounting subsections:
SINGLE GANG ELECTRICAL BOX: CM-333
1a – If using an in-wall box ensure the box is plumb and
square, and flush with the wall surface.
(See Diagram 1)
1b – If using a surface box, ensure it is secure & plumb.
2 – Bring your 2-conductor wire through the back or side
of the enclosure and leave approximately 6” tail for
wiring connection.
3 – Make the electrical connections to the device according
to the wiring section (following).
4 – Using the dip switch located on the end of the unit, set
the operating mode. (See Section 4)
5 – Attach the unit to the enclosure using the two #6-32
screws provided.
6 – Attach the faceplate to the unit using the two black
#6-32 x 3/8 machine screws or tamperproof screws.
Do not overtighten!!
Page 1 of 4