Micro-switch support tab
Auxiliary output for (NO) contact it
closes when the boom completely
opens.
(Contact rated for: 24 V DC - 1 A max)
Auxiliary output contacts
Auxiliary output for (NO) contact it closes
when the boom completely closes.
(Contact rated for: 24 V DC - 1 A max)
Establishing the limit-switch points
Close the inspection hatch and power up the system. Move the boom the check that it is parallel to the road surface when closed and at about
89° when open.
⚠
The boom's opening and closing maneuvers must be performed with the inspection hatch closed.
To correct the boom's vertical position:
- lower the boom;
- open the inspection hatch;
- turn the mechanical closing stop clockwise to increase the boom travel or turn it counter-clockwise to decrease it
.
Fasten the stop with a counter nut
.
To correct the horizontal position:
- raise the boom;
- turn the mechanical closing stop clockwise to increase the boom travel or turn it counter-clockwise to decrease it
.
Fasten the stop with a counter nut
.
Summary of Contents for 001G4040EZT
Page 1: ...English EN Русский RU Italiano IT Français FR FA00583M04 BARRIERE AUTOMATICHE ...
Page 33: ...English EN INSTALLATION MANUAL G4040EZT AUTOMATIC BARRIERS FA00583 EN ...
Page 65: ...Français FR MANUEL D INSTALLATION G4040EZT BARRIÈRES AUTOMATIQUES FA00583 FR ...
Page 97: ...Русский RU ИНСТРУКЦИЯ ПО МОНТАЖУ G4040EZT АВТОМАТИЧЕСКИЕ ДОРОЖНЫЕ ШЛАГБАУМЫ FA00583 RU ...