F6 Maintained action
0 = Deactivated (
default
) / 1 = Activated
The barrier opens and closes by keeping a button pressed. Opening button on contact2-3 and button for closing on contact 2-4. All other
command devices, including radio ones, are excluded.
F9 Obstruction detection
with motor idle
0 = Deactivated (
default
) / 1 = Activated
With the barrier closed, open or after a total stop, the operator stays still if the safety devices (photocells and sensitive edges) detect an
obstruction.
F10 Barrier open signal
output
0 = lit when barrier is up and moving (
default
) /
1 = fl ashes intermittently each half second when opening
when closing it fl ashes intermittently every second
permanently lit with the boom raised
off with the boom lowered
It signals the barrier's status The signal device is connected to contact 10-5.
F11 Encoder
0 = Activated (
default
) / 1 = Deactivated
Managing slow-downs, obstruction detections and sensitivity.
F14 Sensor type selection
0
=
command with transponder sensor or magnetic card reader
/
1 = command with keypad selector (
default
).
Setting the type of sensor for controlling the barrier.
F15 Luminous cord signal
output
0 = Boom in movement
(
default
) /
1 = Boom in movement and closed
It uses intermittent lights to alerts as to the state of the barrier. Luminous cord connected to contact 10-E6.
F18 Additional light
0 = Flashing light (
default
) / 1 = Cycle / 2 = Courtesy
Output on 10-E1.
The fl ashing light works when opening and closing.
The cycle light stays on from the moment in which the barrier starts opening until it closes completely (including the automatic closing time). In
case the automatic closing in not inserted, it stays on only during the movement.
The courtesy light stays on for a fi xed 180 seconds or it can be adjusted, see function F 25.
F19 Automatic closing time
0 = Deactivated (
default
) / 1 = 1 second / ... / 180 = 180 seconds
The automatic-closing wait starts when the opening limit switch point is reached and can be set to between 1 and 180 seconds. The
automatic closing does not activate if any of the safety devices trigger when an obstruction is detected, or after a total stop, or during a power
outage.
F21 Prefl ashing time
0 = Deactivated (
default
) / 1 = 1 second / … / 5 = 5 seconds
Adjusting the pre-fl ashing time of the fl ashing light connected to 10-E1 before each maneuver. The fl ashing time is adjustable from one to ten
seconds.
F22 Working time
5 = 5 seconds / … / 120 = 120 seconds (
default)
Gearmotor working time during opening and closing.
The working time can be set to between 5 seconds and 120 seconds.
F25 Courtesy light time
60 = 60 seconds / … / 180 = 180 seconds (
default
)
Supplementary light, that stays lit during the barrier's opening and closing movement.
The time can be adjusted between fi ve and 120 seconds.
F28 Opening maneuver
speed
70 = Minimum speed / … / 100 = Maximum speed.
Setting the boom's opening speed, calculated as a percentage.
⚠
Warning: the speed parameter fi elds vary depending on the type of boom:
- for jointed booms, of 2 m and 4 m, set the speed percentage to between 70 and 100;
- for booms of 6 m and 8 m, set the speed percentage to between 80 and 100.
F 29 Closing maneuver speed
70 = Minimum speed / … / 100 = Maximum speed.
Setting the boom's closing speed, calculated as a percentage.
⚠
Warning: the speed parameter fi elds vary depending on the type of boom:
- for jointed booms, of 2 m and 4 m, set the speed percentage to between 70 and 100;
- for booms of 6 m and 8 m, set the speed percentage to between 80 and 100.
F 30 Opening slow-down
speed
15 = Minimum speed / … / 40 = Maximum speed
Setting the boom's opening slow-down speed, calculated as a percentage.
⚠
Warning: the speed parameter fi elds vary depending on the type of boom:
- for jointed booms of 2 m, set the slow-down speed percentage to between 20 and 40;
- for booms of 4 m, set the slow-down speed percentage to between 20 and 30;
- for booms of 6 m and 8 m, set the slow-down speed percentage to between 15 and 40.
Summary of Contents for 001G4040EZT
Page 1: ...English EN Русский RU Italiano IT Français FR FA00583M04 BARRIERE AUTOMATICHE ...
Page 33: ...English EN INSTALLATION MANUAL G4040EZT AUTOMATIC BARRIERS FA00583 EN ...
Page 65: ...Français FR MANUEL D INSTALLATION G4040EZT BARRIÈRES AUTOMATIQUES FA00583 FR ...
Page 97: ...Русский RU ИНСТРУКЦИЯ ПО МОНТАЖУ G4040EZT АВТОМАТИЧЕСКИЕ ДОРОЖНЫЕ ШЛАГБАУМЫ FA00583 RU ...