13
-
FA01585M4A
- 04/2021 - © CAME S.p.A. - -
Description
RSLV001 - Slave module for operators (002RSE module included).
RSLV001AC - Slave module for access (002RSE module included).
The device only works if paired with an RGSM001/RGSM001AC or RETH001 MASTER module.
A
Description of parts
1
P1 button for resetting or rebooting the module
Press and hold for 10 seconds to reset the module to its
factory settings.
Press and hold for more than 3 seconds and then release
to reboot the module.
2
Interface 485 PIN B
3
Interface 485 PIN A
4
GND CRP / - Power supply
5
+ Power supply
6
(rosso) Relay 1, 30V DC - 1A (max) N.O.
7
(blu) Relay 2, 30V DC - 1A (max) N.O.
8
(giallo) Input 1 (24V DC max)
9
(bianco) Input 2 (24V DC max)
10
(nero) Common inputs
11
POWER LED (green)
12
OUT2 LED (red)
13
OUT1 LED (red)
14
Function control board (RSE)
15
CONNECT LED (red)
This device is fi tted with an external wire antenna which must not be removed.